10-13
User
Guide

for

the

Cisco

Application

Networking

Manager

5.2
OL-26572-01
Chapter
10






Configuring

Parameter

Maps
Configuring
Optimization

Parameter

Maps
Duration
For

Browser
Freshness
(Seconds)
Field
that

appears

if

the

Set

Browser

Freshness

Period

option

is

not

configured.
Enter
the

number

of

seconds

that

objects

in

the

client’s

browser

are

considered

fresh.

Valid

entries
are
0

to

2147483647

seconds.
Response
Codes

To
Ignore
(Comma
Separated)
Comma-separated
list

of

HTTP

response

codes

for

which

the

response

body

must

not
be

read.

For
example,
an

entry

of

302

indicates

that

the

ACE

is

to

ignore

the

response

body

of

a

302

(redirect)
response
from

the

origin

server.

Valid

entries

are

unquoted

text

strings

with

a

maximum

of

64
alphanumeric
characters

from

100

to

599,

inclusive.
Appscope
Optimize
Rate
(%)
Percentage
of

all

requests
or
sessions

to

be
sampled
for

performance

with

acceleration

(or
optimization)
applied.

All

applicable

optimizations

for

the

class

will

be

performed.

Valid

entries
are
from

0

to

100

percent.

The

default

is

10

percent.

The

sum

of

this

value

and

the

value

entered
in
the

Passthru

Rate

Percent

field

must

not

exceed

100.
Appscope
Passthrough
Rate
(%)
Percentage
of

all
requests
or

se

ssions

to

be

sampled

for


performance

without

optimization.

No
optimizations
for

the

class

will

be

performed.

Valid

entries

are

from

0

to

100.

The

default

is

10
percent.
The

sum

of

this

value

and

the

value

entered

in

the

Optimize

Rate

Percent

field

must

not
exceed
100.
Max.
Number

for
Parameter
Summary
Log
(Bytes)
Maximum
number

of

bytes

that
are
to
be
logged

for


each
parameter
value

i

n
the

parameter
summary
of

a

transaction

log

entry

in

the

statistics

log.

If

a

parameter

value

exceeds

this

limit,

it
is
truncated

at

the

specified

limit.

Valid

entries

are

from

0

to

10,000

bytes.
Max.
For

Post

Data

to
Scan
for


Logging
(KBytes)
Maximum
number
of
kilobytes

of

POST

data

that

the

ACE

is

to

scan

for

parameters

for

the

purpose
of
logging

transaction

parameters

in

the

statistics

log.
Valid
entries

are

from

0

to

1000

KB.
String
For

Grouping
Requests
String
that

t

he

ACE

uses
to
sor

t

requests

for


AppScope

reporting.

The
string
can

contain
a
URL
regular
expression

that

defines

a

set

of

URLs

in

which

URLs

that

differ

only

by

their

query
parameters
are

to

be

treated

as

separate

URLs

in

AppScope

reports.
For
example,

to

define

a

string

that

is

used

to

identify

the

URLs
http://server/catalog.asp?region=asia
and

http://server/catalog.asp?region=america

as

two

separate
reporting
categories,

you

would

enter

http_query_param(region).
Valid
entries

are

from

1

to

255

characters

and

can

contain

the

parameter

expander

functions

listed
in
Ta

b

l

e


10-7 .
Base
File

Anonymous
Level
Base
file

anonymous

level.
Information
that

is

common

to

a

large

set
of
users

is
generally
not
confidential
or

user-specific.

Conversely,

information

that

is

unique

to

a

specific

user

or

a

small

set
of
users

is

generally

confidential

or

user-specific.

The

anonymous

base

file

feature

enables

the
ACE
to

create

and

deliver

condensed

base

files

that

contain

only

information

that

is

common

to

a
large
set

of

users.

No

information

unique

to

a

particular

user,

or

across

a

very

small

subset

of

users,
is
included

in

anonymous

base

files.
Enter
the

value

for

base

file

anonymity

for

the

all-user

condensation

method.

Valid

entries

are

from
0
to

50.

The

default

is

0,

which

disables

the

base

file

anonymity

feature.
Table
10-6
Optimization
Parameter

Map

Attributes

(continued)
Field
Description