Chapter
8






Configuring

Real

Servers

and

Server

Farms
Configuring
Health

Monitoring
Configuring
an

OID

for

SNMP

Probes
You
can

configure

OID

queries

t

o

probe

t

he

server.

When

t

he

ACE

sends

a

pr

obe

with

an

SNMP

OID
query,
the

ACE

uses

the

retrieved

value

as

input

to

the

least-loaded

algorithm

for

load-balancing
decisions.
Least-loaded

load

balancing

bases

the

server

selection

on

the

server

with

the

lowest

load
value.
If

the

retrieved

value

is

within

the

configured

threshold,

the

server

is

marked

as

passed.

If

the
threshold
is

exceeded,

the

server

is

marked

as

failed.
The
ACE

al

lows

a

maximum

of

ei

ght

OID

queries

to

pr

obe

the

ser

ver.
Assumption
An
SNMP

probe

has

been

configured.

See

the

“Configuring

Health

Monitoring

for

Real

Servers”

section
on
page

8-51

for

more

information.
Procedure
Step
1
Choose
Config
>

Devices

>

context

>

Load

Balancing

>

Health

Monitoring.
The
Health

Monitoring

t

able

ap

pears.
Step
2
In
the

Health

Monitoring

table,

choose

the
SNMP
probe

for
which
you
want
to
specify

an

OID.
The
SNMP

OID

for

Server

Load

Query

table

appears.
Step
3
In
the

SNMP

OID

for

Server

Load

Query

table,

click
Add
to

add
an
entry,

or

choose

an

existing

entry
and
cl

ick

Edit

to

modify

it.
The
SNMP

OID

configuration

pane

appears.
Step
4
In
the

SNMP

OID

field

of
the
SNMP
OID

configuration

pane,

enter

the
OID
that

the

probe
is
to

use

to
query
the

server

for

a

value.
Valid
entries

are

unquoted

strings

with

a

maximum

of

255

alphanumeric

characters

in

dotted-decimal
notation,
such

as

.1.3.6.1.4.2021.10.1.3.1.

The

OID

string

is

based

on

the

server

type.
Step
5
In
the

Max.
Absolute
Server

Load

Value
field,
enter

the
OID

value

in

the

form

of
an
integer

and

to
indicate
that

the

retrieved

OID

value

is

an

absolute

value

instead

of

a

percent.
Valid
entries

ar

e

fr

om

1

t

o

4294967295.
When
the

ACE

sends

a

probe

with

an

SNMP

OID

query,

the

ACE

uses

the

retrieved

value

as

input

to

the
least-loaded
algorithm

for

load-balancing

decisions.

By

default,

the

ACE

assumes

that

the

retrieved

OID
value
is

a

percentile

value.

Use

this

option

to

specify

that

the

retrieved

OID

value

is

an

absolute

value.
Step
6
In
the

Server

Load

Threshold

Value

field,

specify

the

threshold

at

which

the

server

is

to

be

taken

out

of
service
as


follows:


When
the

OID

value

is

based

on

a

percent,

valid

entries

are

integers

from

1

to

100.


When
the

OID

is

based

on

an
absolute

value,

valid

entries

are

from

1

to
the
value

specified
in
the
Maximum
Absolute

Server

Load

Value

field.
Step
7
In
the
Server

Load
Weighting
field,

enter
the
weight

to

assign
to
this

OID

for
the
SNMP

probe.
Valid
entries

ar

e

fr

om

0

t

o

16000.
Step
8
Do
one

of

the

following:


Click
Deploy
Now

to

deploy
this

configuration

on

t

he
ACE
and

save

your

entries

t

o

the
running-configuration
and

startup-configuration

files.


Click
Cancel
to

exit

this

procedure

without

saving

your

entries

and

to

return

to

the

SNMP

OID

table.