5-71
User
Guide

for

the

Cisco

Application

Networking

Manager

5.2
OL-26572-01
Chapter
5






Importing

and

Managing

Devices
Managing
Devices


Override—Map
the

VMs
the
specified
ACE

real

servers.

This

option
is

available

only

when

you
have
one

VM

selected

from

the

All

Devices

table

(see

Step

2 ).

When

you

choose

Override,

ANM
displays
the

Select

Real

Server(s)

table

of

available

ACE

real

servers

that

includes

the

device
information,
real

server

name,

IP

address,

port

number,

and

server

farm

to

which

the

real

server
belongs.
Step
7
If
you

chose

t

he
Override
mapping

rul

e,

do

one


or

bot

h

of


the
following:


Check
the

checkbox
next

to

the

real

servers

to

map

the

selected

real

servers

to

the

VM.

To

select

all
of
the

available

real

servers,

check

the

Device

checkbox

located

at

the

top

of

the

table.


Click
Add

to

add

a

new

real

server.

The

Add

a

Real

Server

popup

window

appears.

Define

the
new
real
server

as

de

scribed

in

Ta

b

l

e


5-24

and

click

Deploy

Now.
Step
8
In
the

VM

Mappings

window,

click
OK
to

save

the

new

mapping

rule
or
Cancel
to

cancel

the

change.
Related
Topics


Configuring
Real
Servers,
page
8-5


Importing
VMware

vCenter

Servers,

page
5-24


Configuring
VMware

vCenter

Ser

ver

Primary

Attributes,

page
5-41
Instructing
ANM

to

Recognize

an

ACE

Module

Software

Upgrade
When
you

upgrade

the

software

of

an

ACE

module

that

has

been

imported

to

the

ANM

database,

perform
the
procedure

outlined

in

this

section

to

enable

ANM

to

recognize

the

updated

release

and

display
features
and

functions

in

the

ANM

GUI

that

ar

e

appropriate

for

the

ACE

module

software

upgrade.
For
example,

if

an

imported

ACE

module

contains

software

Version

A2(2.1),

and

you

wish

to

upgrade
to
software

Version

A2(3.0)

to

take

advantage

of

features

such

as

backup

and

restore,

you

must

perform
the
steps

outlined

below

to

instruct

ANM

to

recognize

the

upgraded

ACE

module

software

version

and
Ta
b

l

e


5-24
Adding
a

Real

Server

for

VM

Mapping
Item
Description
Real
Server

Name
Unique
name

for

this

server

or

accept

the

automatically

incremented

value

in

this

field.

Valid
entries
are

unquoted

text

strings

with

no

spaces

and

a

maximum

of

64

characters.
Real
Server

IP

Address
Unique
IP

address

in

dotted-decimal

format

(such

as

192.168.11.1).

The

IP

address

cannot

be

an
existing
virtual

IP

address

(VIP).
Real
Server

Port
Port
used

for

communication

with

the

real

server.
Real
Server

Weight
Weight
to

be

assigned

to

this

real

server

in

a

server

farm.

Valid

entries

are

from

1

to

100,

and

the
default
is

8.
Real
Server

State
State
of

the

real

server

when

deployed:


In
Service—The

real

server

is

in

service.


Out
Of

Service—The

real

server

is
out
of

service.
ACE
Virtual

Context
Virtual
context

that

is

associated

with

the

real

server.
Serverfarm
Server
farm

to

which

the

real

server

belongs.
Vi
r

t

u

a

l


S

e

r

v

e

r

s
Virtual
server

that

is

associated

with

the

real

server.