SOL0A00

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0A00   ! ERROR DURING UPDATE OF ACTIVITY FILE:(&02) ENTER TSN.        

Meaning

The (&02) activity file could not be updated. (File manually  
deleted in the meantime?) Further installations of this     
package cause procedure abortion or integration of delivery 
units that have already been installed.                     
   &02  =  File name of activity file                       

Response

Action: Please check which delivery units must still be       
        integrated (delivery documentation). If the         
        A.SOLIS.B.package.ishort file is not cataloged,     
        select it from the delivery volume.                 

SOL0A01

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0A01     PACKAGE:(&01) SOLIS2 (KAORT) IS BEING UPDATED                

Meaning

The residence areas in the SOLIS2 database are updated and    
all delivery groups concerned are released.                 
   &01  =  Package number                                   

Response

Action: none                                                  

SOL0A02

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0A02   ! (&00) PACKAGE:(&01) ERROR DURING FILE TRANSFER - PLEASE INFORM EXPERT: (&02)                                                         

Meaning

The desired file transfer could not be performed properly.    
For more information, see the error log.                    
   &00  =  No. of processing step                           
   &01  =  Package number                                   
   &02  =  Name of expert                                   

Response

Action: Determine cause and answer message with tsn.0/1.      
  TSN.0  The processing step is repeated.                   
  TSN.1  File transfer aborts. Delivery groups concerned may
         have to be unlocked manually. File transfer must be
         repeated (FUNCTION:BEWE).                          
  TSN.2  The error is ignored.                              

SOL0A03

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0A03   ! ACTIVITY FILE:(&01) NOT CATALOGED - PLEASE INFORM EXPERT:(&02)

Meaning

The (&01) package lacks an activity file. This file is        
created by the SOLIS2 application (FUNCTION:LIEF) and deleted
automatically after the SOLIS.K.package procedure has       
executed properly.                                          
For more information, see SOLIS.L.GL.packagename.           
   &01  =  Package number                                   
   &02  =  Name of expert                                   

Response

Action: The job must be reset in SOLIS1 (ASAP) and then       
        regenerated with SOLIS2 (LIEF),                     
  or    load the first delivery tape with REP=NO and restart
        the ENTER procedure SOLIS.E.AUS.package.            

SOL0A04

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0A04     PACKAGE:(&01) SOLIS2 DB IS BEING UPDATED                     

Meaning

Modifications are made in the SOLIS2 database.                
   &01  =  Package number                                   

Response

Action: none                                                  

SOL0A05

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0A05   ! PACKAGE:(&01) ERROR DURING UPDATE OF SOLIS2 DB - PLEASE INFORM EXPERT: (&02)                                                         

Meaning

The SOLIS2 database could not be updated. The W2GEN/W2ANSCH   
program terminated abnormally.                              
   &01  =  Package number                                   
   &02  =  Name of expert                                   

Response

Action: Determine cause and answer with:                      
  TSN.0  The processing step is repeated.                   
  TSN.1  The processing terminates improperly.              
  TSN.2  The error is ignored.                              

SOL0B00

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0B00     RESOURCE CHECK STARTED

Meaning

The resources required for installation (utilities, devices)  
are checked for availability.                               

Response

Action: none                                                  

SOL0B01

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0B01   ! (&00) * UTILITY (&02) OR DEVICE TYPE (&03) NOT AVAILABLE - TSN.0=REPEAT, TSN.1=ABORT, TSN.2=IGNORE                                  

Meaning

The (&02) utility or (&03) device type is not available. For  
more information on the cause of the error, see the error   
log.                                                        
   &00  =  No. of installation step performed               
   &02  =  Name of utility                                  
   &03  =  Designation of backup volume                     

Response

Action:                                                       
  -   TSN.0  The installation step is repeated.             
  -   TSN.1  The load procedure aborts and must be restarted
             with (/DO A.DO.ishort.package or               
             /E SOLIS.K.pack.ishort) after error elimination.
  -   TSN.2  The error is ignored.                          

SOL0B02

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0B02     PACKAGE:(&01) SOLIS1 DB INTERFACE IS BEING UPDATED           

Meaning

The package is marked for SOLIS1 as having been delivered.    

SOL0B03

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0B03   ! (&00) PACKAGE:(&01) ERROR DURING UPDATE OF SOLIS1 INTERFACE - TSN. 0=REPEAT AFTER TSN.1=ABORT TSN.2=IGNORE INFORM EXPERT:(&02)     

Meaning

An error has occurred during update of the SOLIS1 interface.  
For more information on the cause of the error, see the error
log.                                                        
   &00  =  No. of installation step performed               
   &01  =  Package number                                   
   &02  =  Name of expert                                   

Response

Action: Answer message and inform expert:(&02).               

SOL0B04

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0B04     PACKAGE:(&01) RELEASE NOTICES ARE BEING PROCESSED            

Meaning

The release notices for the delivery concerned are stored in  
the SOLIS.L.FGM.package file.                               

Response

Action: none                                                  

SOL0B05

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0B05   ! (&00) PACKAGE:(&01) ERROR DURING RELEASE NOTICE PROCESSING - PLEASE INFORM EXPERT:(&02)                                             

Meaning

The release notices for the delivery concerned could not be   
provided without errors occurring.                          

Response

Action: Determine cause and answer message with tsn.0/1.      
  TSN.0  The processing step is repeated.                   
  TSN.1  The load procedure aborts. The Enter procedure     
         SOLIS.E.AUS.package must be restarted. The package 
         may have to be reset and regenerated.              
  TSN.2  The error is ignored.                              

SOL0B08

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0B08   ! PACKAGE:(&01) ERROR DURING CONFIRMATION TO D10 - INFORM EXPERT:(&02) - SPECIFY TSN.                                                 

Meaning

Integration of the delivery/update could not be confirmed at  
the central office.                                         
   &01  =  Package number                                   
   &02  =  Name of expert                                   

Response

Action: Answer message with tsn. and inform expert:(&02).     
        The SOLIS.D.package.DO.RUECK procedure must be      
        started manually.                                   
NOTE: The log files created for this delivery are not deleted
automatically! Once the package has been processed, please  
enter /DELETE-FILE **package* under SW201.                  

SOL0B09

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0B09     FILE:(&01) FILE TRANSFER STARTED                             

Meaning

File transfer for requested file has started.                 

SOL0B10

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0B10   ! PACKAGE:(&01) ERROR DURING FILE TRANSFER - INFORM EXPERT:(&02) - SPECIFY TSN.                                                      

Meaning

The library could not be transferred with FILE-TRANSFER.    
(TRANS-FILE initiated SPIN-OFF.)                            
   &01  =  File                                             
   &02  =  Name of expert                                   

Response

Action: Determine cause and answer message with tsn.0/1.    
  TSN.0  The processing step is repeated.                   
  TSN.1  Transfer aborts. The Enter procedure must be       
         restarted.                                         
  TSN.2  The error is ignored.                              

SOL0B90

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0B90     ERROR ((&02)) HAS OCCURRED                                   

Meaning

   &02  =  error code (30/31/TERMJ or COPY error)             

Response

Action: none                                                  

SOL0B94

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0B94   ! PLEASE CHECK ERROR LOG:(&02)                                 

Meaning

A runtime log has been created for the current error          
(condition) and has been cataloged under the above file name.

Response

Action: Print out log with: /PRINT-DOC filename.

SOL0B95

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0B95     (&02) LOG:(&04) BECOMES (&03)                                

Meaning

The (&02) log has been created under the name (&04).          
The file becomes (&03).                                     
   &02  =  Log type                                         
   &03  =  Action (submit/print)                            

Response

Action: none                                                  

SOL0B99

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0B99   LOGGING FILE:(&03) DMS ERROR:(&02) - TSN.0=REPEAT, TSN.2=IGNORE

Meaning

Due to the current error condition, messages of the MSGSOL7   
module could not be stored in the logging file (possible    
cause of error: /SH-FILE of another user).                  

Response

Action: Determine cause of error.                             
  TSN.0  File access is repeated (if possible).             
  TSN.2  The error is ignored. The subsequent message is not
         stored in the logging file.                        

SOL0000

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0000   ======== L O G O N   PACKAGE:(&01) - SOLIS2 VER:(&02)          

Meaning

&01  =   Package name                                        
&02  =   Correction level SOLIS2                           

SOL0001

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0001     PACKAGE:(&01) STARTED

Meaning

Processing of the delivery with package number &01 has been  
started.                                                    
&01  =   Package name                                      

Response

Action: none                                                  

SOL0002

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0002   ! ERROR WHEN LOGGING FILES (&02) ARE OPENED

Meaning

The SYSLST/SYSOUT file (&02) could not be assigned (ASSIGN-SYSLST /
ASSIGN-SYSOUT command rejected). The load procedure was presumably
started several times or SPOOLOUT was active.    
  &02   =   Name of SYSLST/SYSOUT file                      

Response

Action:  Control processes (/SHOW-JOB-STATUS *JOB-NAME(EINSPIEL),
         INFORMATION=*PROGRAM) and check SPOOLOUT (printer may be
         inop). Enter TSN. and restart job.

SOL0003

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0003     PACKAGE:(&01) PROCESSING TERMINATED PROPERLY                 

Meaning

Processing of the delivery with package number &01 has       
terminated properly. The runtime log has been stored under  
SOLIS.L.GL.package.time.                                    
&01  =   Package name                                      

Response

Action: none                                                  

SOL0004

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0004   ! PACKAGE:(&01) PROCESSING TERMINATED WITH MESSAGES - PLEASE ENTER TSN.                                                               

Meaning

Messages that were answered with tsn. or tsn.2 (ignore)       
appeared during the load procedure. Please check the messages
concerned (all marked by !) with the SOLIS.L.MSG.package    
file.                                                       
&01  =   Package name                                      

Response

Action: Continue process with tsn. and check the              
SOLIS.L.GL.package.time runtime log after LOGOFF.           

SOL0005

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0005   ! PACKAGE:(&01) PROCESSING ABORTED - PLEASE ENTER TSN.         

Meaning

Installation has terminated abnormally (SOLIS message was     
answered with TSN.1 (abort)).                               
The SYSLST log SOLIS.L.GL.package.time must be checked and  
measures taken to eliminate the error.                      
&01  =   Package name                                      

Response

Action: Answer message with tsn./check log!                   

SOL0006

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0006   ======== L O G O F F   PACKAGE:(&01)                           

Meaning

&01  =   Package name                                        

SOL0007

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0007   ======== A B E N D     PACKAGE:(&01)                           

Meaning

&01  =   Package name                                        

SOL0008

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0008   ! PACKAGE:(&01) GENERATION ABORTED                             

Meaning

Processing aborts due to an error.                            
A SOLIS message was answered with TSN.1 (abort) during      
execution. The error log must be checked and measures       
taken to eliminate the error.                               
&01  =   Package name                                      

Response

Action: Check error log. If necessary, reset delivery.        

SOL0009

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0009     PACKAGE:(&01) GENERATED                                      

Meaning

The (&01) delivery has been generated and can be delivered    
to the customer.                                            
&01  =   Package name                                      

Response

Action: none                                                  

SOL0010

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0010   ! PACKAGE:(&01) GENERATION TERMINATED WITH WARNINGS            

Meaning

Messages that were answered with tsn. (ACCEPT) or tsn.2       
(IGNORE) appeared during generation of the delivery:(&01).  
The SOLIS.L.MSG.package log file must be checked for these  
messages.                                                   
   &01  =  Package name                                     
   &02  =  Name of expert                                   

Response

Action: Check log. It must be ensured that the data volume    
was generated properly (otherwise we can count on customer  
complaints).                                                
NOTE: The log files generated for this delivery are not     
deleted automatically. If the package has been generated    
properly, please enter /DELETE-FILE **package* under SW201.

SOL0011

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0011     SU:(&02) PATH:(&03)                                          

Meaning

Software unit (&02) is installed under user ID (&03).         

Response

Action: none                                                  

SOL0012

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0012     PACKAGE:(&01) EXECUTE RESTART FUNCTION ? ENTER TSN.1=YES, TSN.2=NO                                                                  

Meaning

The Enter procedure for package:(&01) has already been        
started once before, but errors led to procedure abortion.  
You have the option of continuing the Enter procedure from  
the faulty installation step or restarting the entire       
procedure.                                                  

Response

Action:                                                       
  -   TSN.1  Start at installation step                     
  -   TSN.2  Repeat all installation steps                  

SOL0013

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0013     ACTIVATION TIMESTAMP: (&01) EXECUTE RESTART FUNCTION ? ENTER TSN.1=YES, TSN.2=NO?                                                   

Meaning

The Enter procedure for activation timestamp:(&01) has already
been started once before, but errors led to procedure       
abortion.                                                   
You have the option of continuing the Enter procedure from  
the faulty installation step or restarting the entire       
procedure.                                                  

Response

Action:                                                       
  -   TSN.1  Start at installation step                     
  -   TSN.2  Repeat all installation steps                  

SOL0014

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0014   * DETAILED RUNTIME LOG SEE:(&02)                               

Meaning

A detailed runtime log has been generated under the file name (&02).
This file can be printed out with:
/PRINT-DOCUMENT (&02),DOC-FORM=*TEXT(LINE-SPACING=*BY-EBCDIC-CONTROL)

Response

Action: none                                                  

SOL0067

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0067     PACKAGE:(&01) FUNCTION:UEBN TERMINATED                       

Meaning

The (&01) package has been loaded without errors and the      
database updated. After any delivery or update barriers have
been removed, the delivery components can be delivered to the
customer.                                                   

Response

Action: none                                                  

SOL0068

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0068   ! PACKAGE:(&01) FUNCTION:UEBN ABORTED - PLEASE INFORM (&02)    

Meaning

The Enter process generated by (SOLIS2 UEBN) has terminated   
abnormally. The products delivered in the (&01) package have
not been updated in the database and cannot be forwarded to 
the customer. For more information, see the error log.      
   &01  =  Package name                                     
   &02  =  Name of expert                                   

Response

Action: Enter tsn. and determine cause. Restart the Enter     
        process SOLIS.E.ANSCH.package.                      

SOL0069

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0069     PACKAGE:(&01) FUNCTION:EINSP TERMINATED                      

Meaning

The EINSP ($SW200.DO.SOL) funtion has terminated properly.    
The delivery can be transferred to the database with SOLIS2 
(UEBN).                                                     
   &01  =  Package name                                     

Response

Action: Call SOLIS2 function UEBN.                            

SOL0070

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0070   ! PACKAGE:(&01) FUNCTION:EINSP ABORTED - PLEASE INFORM (&02)   

Meaning

The EINSP ($SW200.DO.SOL) function has terminated abnormally. 
This error may have been caused by:                         
- no public space available in the production ID           
- error during delivery volume transfer                    
- error during processing of RMS delivery sets             
The process terminates after TSN. has been entered.         
For more information on the error condition, see error log! 
   &01  =  Package number                                   
   &02  =  Name of expert                                   

Response

Action: Enter TSN. and check SOLIS.L.GL.(&01) error log.      
        Determine cause and restart the DO.SOL procedure    
        (FUNCTION:EINSP).                                   

SOL0071

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0071     PACKAGE:(&01) VSN:(&02) - DO NOT RELEASE                     

Meaning

The EINSP ($SW200.DO.SOL) function has aborted. The delivery  
volumes concerned must not be released.                     
   &01  =  Package name                                     
   &02  =  VSN of delivery volume                           

Response

Action: Repeat DO.SOL function EINSP.                         

SOL0100

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0100     DATA BACKUP STARTED - OUTPUT VOLUME:(&02)                    

Meaning

Files that are modified when this delivery is transferred are 
saved on the output volume (PLAM library, magnetic tape or  
cartridge).                                                 
   &02  =  Backup volume                                    

Response

Action: If necessary, provide data volume.                    

SOL0101

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0101   ! (&00) * ERROR DURING DATA BACKUP FOR (&02) - TSN.0=REPEAT, TSN.1=ABORT, TSN.2=IGNORE                                                

Meaning

The volume (tape/cartridge/library) used for backup could not 
be generated properly (files are open or protected by a     
password/Mount message was answered with TSN.NO). The       
ARCHIVE or LMSCONV utility was terminated with error option 
30/31 or TERMJ.                                             
   &00  =  No. of processing step                           
   &02  =  Designation of backup volume                     

Response

Action:                                                       
  -   TSN.0  The installation step is repeated.             
  -   TSN.1  The load procedure aborts and must be          
             restarted with (/DO A.DO.ishort.package or     
             /E SOLIS.K.pack.ishort) after error elimination.
  -   TSN.2  The error is ignored.                          

SOL0102

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0102     FILE SELECTION STARTED - INPUT FROM:(&02)                    

Meaning

The selection of files from:(&02) is started.                 
&02  =   Delivery volume                                   

Response

Action: none                                                  

SOL0103

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0103   ! (&00) * ERROR DURING FILE TRANSFER FROM (&02) - TSN.0=REPEAT, TSN. 1=ABORT, TSN.2=IGNORE                                           

Meaning

File transfer from the (&02) delivery volume could not be     
performed properly. (Files to be replaced are open or       
protected by a password/Mount message was answered with     
TSN.NO/hardware error occurred.)                            
&02  =   Delivery volume                                   

Response

Action:                                                       
  TSN.0  The installation step is repeated.                 
  TSN.1  The load procedure aborts and must be restarted with
         /CALL-PROC A.DO.ishort.package or
         /ENTER-JOB SOLIS.K.package.ishort after error elimination.
  TSN.2  The load procedure is continued. Files not         
         transferred can be determined and transferred      
         manually with the automatically generated SYSLST   
         log.                                               

SOL0109

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0109     PACKAGE:(&01) PROVIDE INPUT VOLUME:(&02)                     

Meaning

The (&02) volume is required for the (&01) delivery           
   &01  =  Package number                                   
   &02  =  Designation of volume                            

Response

Action: Provide necessary input volume.                       

SOL0110

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0110   ! (&00) * PACKAGE:(&01) ERROR DURING PROCESSING OF VOLUME:(&03)  - PLEASE INFORM EXPERT:(&02)                                       

Meaning

Processing of the (&03) volume has terminated abnormally.     
(ARCHIVE terminated with TERMJ or SW31=ON.) For more        
information, see the error log.                             
   &00  =  No. of processing step                           
   &01  =  Package number                                   
   &02  =  Name of expert                                   
   &03  =  Designation of volume                            

Response

Action: Determine cause and answer message with tsn.0/1.      
  TSN.0  The processing step is repeated.                   
  TSN.1  The load procedure aborts. The Enter procedure     
         SOLIS.E.AUS.package must be restarted. The package 
         may have to be reset and regenerated.              
  TSN.2  The error is ignored.                              

SOL0111

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0111     PACKAGE:(&01) PROVIDE OUTPUT VOLUME:(&02)                    

Meaning

   &01  =  Package number                                     
   &03  =  Designation of volume                            

Response

Action: Provide requested output volume.                      

SOL0112

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0112   ! (&00) PACKAGE:(&01) ERROR DURING PROCESSING OF DELIVERY INFOR MATION - PLEASE INFORM EXPERT:(&02)                                 

Meaning

The delivery documentation has been processed abnormally      
(FMS error - library locked/element non-existent). For more 
information, see the error log !                            
   &00  =  No. of processing step                           
   &01  =  Package number                                   
   &02  =  Name of expert                                   

Response

Action: Determine cause and answer message with tsn.0/1.      
  TSN.0  The processing step is repeated.                   
  TSN.1  The load procedure aborts. The package must be     
         reset and regenerated.                             
  TSN.2  The error is ignored.                              

SOL0113

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0113     PACKAGE:(&01) DOCUMENTATION IS STORED IN FMSLIB              

Meaning

The documentation (RZ order, delivery cover letter, customer  
docum. enclosed in delivery) is stored in the FMSLIB (STGL).
   &01  =  Package number                                   

Response

Action: none                                                  

SOL0200

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0200     FILE ATTRIBUTES ARE RESET                                    

Meaning

Files that have already been cataloged and modified during    
delivery processing are set to AC=WRITE/RETPD=0. Any entered
passwords are removed. All file attributes are restored     
after processing.                                           

Response

Action: none                                                  

SOL0201

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0201   ! FILE (&02) IS LOCKED ! - PLEASE ENTER /HELP SOL0201          

Meaning

The (&02) file is open (assigned to other TSN) or provided    
with a password that the procedure does not recognize.      
   &02  =  File name                                        

Response

Action:                                                       
Manually reset file attributes with the following command:  
/MODIFY-FILE-ATTRIBUTES (&02),ACCESS=*WRITE,RETENTION-PERIOD=0
The process can then be continued with TSN.                 

SOL0202

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0202     RESERVATION FOR NEWLY DELIVERED FILES STARTED                

Meaning

All files that are provided with this delivery and not yet    
cataloged in the system are stored by means of              
/CREATE-FILE file,SUPPORT=*PUBLIC-DISK(SPACE=*RELATIVE(
                  PRIMARY-ALLOCATION=size))

Response

Action: none                                                  

SOL0204

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0204   ! (&00) * DMS ERROR WHILE ATTEMPTING TO SET UP NEW FILES SUPPLIED WITH THE DELIVERY - TSN.0=REPEAT, TSN.1=ABORT, TSN.2=IGNORE         

Meaning

See the error message in the logging file.                    
The cause of error may be:                                  
- 1. Storage space is saturated                            
- 2. User ID has not been created                          
- 3. Incorrect user ID was entered in the user dialog      
      (procedure: A.DO.ishort.package)                      
- 4. Access error on file.                                 
   &00  =  No. of processing step                           

Response

Action:                                                       
- 1. Provide necessary storage space and answer the load   
      procedure with tsn.0.                                 
- 2. Enter user ID and answer process with tsn.0.          
- 3. If the user ID is incorrect, terminate the process with
      tsn.1 and restart it with the A.DO.ishort.package     
      procedure. If you enter tsn.2, the error will be      
      ignored and the load procedure will continue.         
- 4. Change the access attributes or remove active file    
      protection and answer process with tsn.0.             

SOL0205

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0205   ! ERROR DURING RESTORATION - FILE:(&00) (ACCESS=(&01),RETPD=(&02), SHARE=(&03),BACKUP=(&04),(&05)                                      

Meaning

The (&00) file could not be provided with the corresponding   
&01,&02,&03,&04,&05 attributes. This file must be manually  
recataloged after the Enter procedure has executed.         
   &00 - &05  File attributes                               

Response

Action:                                                       
Manually enter file attributes with the following command:  
/MODIFY-FILE-ATTRIBUTES (&00),ACCESS=(&01),RET-PERIOD=(&02),
                        USER-ACCESS=...,SAVE=...,MIGRATE=...

SOL0206

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0206     DELETE TEMPORARY FILES ? - TSN.1=DELETE, TSN.2=DO NOT DELETE 

Meaning

During the load procedure, SOLIS creates temporary files      
that are no longer required after the delivery has been     
successfully transferred. You can decide whether you want   
to keep these files. Temporary files include                
  -   RMS delivery sets                                     
  -   parked REP files (RMS input files)                    
  -   input libraries/temporary procedures                  
  -   work files                                            

Response

Action:                                                       
  -   TSN.1  The temporary files are deleted.               
  -   TSN.2  The temporary files are not deleted.           

SOL0207

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0207     TEMPORARY FILES ARE BEING DELETED                            

Meaning

Files that are only required during the load procedure        
are deleted. Temporary files include input libraries,       
DO and ENTER procedures and RMS delivery sets.              

Response

Action: none                                                  

SOL0208

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0208     FILE CHARACTERISTICS ARE BEING RESTORED                      

Meaning

Files which were already stored before transfer to the system 
catalog are reset to their original characteristics.        
New files are cataloged according to SOLIS conventions.     

Response

Action: none                                                  

SOL0209

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0209     FILE TRANSFER FROM THE PARK ID STARTED                       

Meaning

Delivered files are transferred from the park ID by means of  
the /COPY-FILE command.                                          

Response

Action: none                                                  

SOL0210

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0210   ! ERROR IN /COPY-FILE (&02),(&03)

Meaning

The COPY-FILE command has aborted. The file could not be copied.   
   &02  =  Input file                                       
   &03  =  Output file                                      

Response

Action:                                                       
  - Perform COPY-FILE command manually. Watch out for errors!    

SOL0212

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0212   ! (&00) * ERROR DURING TRANSFER FROM PARK ID:(&02) - ENTER TSN.0=REPEAT, TSN.1=ABORT, TSN.2=IGNORE                                    

Meaning

Not all files could be transferred during file transfer from  
the park ID (see previous SOL0210 message(s)).              
   &00  =  No. of installation step                         
   &02  =  Name of user ID for park installation            

Response

Action: Eliminate error and answer message with:              
  -   TSN.0  The processing step is repeated.               
  -   TSN.1  Processing aborts and must be restarted after  
             error elimination.                             
  -   TSN.2  The error is ignored.                          

SOL0213

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0213   ! (&00) * PACKAGE:(&01) ERROR DURING (TEMPORARY) INSTALLATION - PLEASE INFORM EXPERT:(&02)                                            

Meaning

Not all files required for the (&01) package could be         
provided (no space on PUBLIC/PRIVATE volume?).              
   &00  =  No. of processing step                           
   &01  =  Package number                                   
   &02  =  Name of expert                                   

Response

Action: Determine cause and answer message with tsn.0/1.      
  TSN.0  The processing step is repeated.                   
  TSN.1  The load procedure aborts. The Enter procedure     
         SOLIS.E.AUS.package must be restarted. The package 
         may have to be reset and regenerated.              
  TSN.2  The error is ignored.                              

SOL0214

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0214     PACKAGE:(&01) INSTALL FILES (TEMPORARILY)                    

Meaning

self-explanatory                                              
   &01  =  Package number                                   

Response

Action: none                                                  

SOL0215

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0215     PACKAGE:(&01) KAORT:(&03) FILE ATTRIBUTES ARE RESET          

Meaning

Files with (&03) residence are set to ACC=WR and any existing 
passwords are removed.                                      
   &01  =  Package number                                   
   &03  =  Component residence                              

Response

Action: none                                                  

SOL0216

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0216   ! (&00) * PACKAGE:(&01) ERROR WHEN KAORT:(&03) FILE ATTRIBUTES ARE RESET - PLEASE INFORM EXPERT:(&02)                                 

Meaning

A DMS error has occurred when a file having component         
residence (&03) was accessed. For more information, see the 
error log. The error may arise when files are deleted or    
passwords are not entered in accordance with the procedure  
between SOLIS2 (LIEF) generation and the start of           
SOLIS.E.AUS.package.                                        
   &00  =  No. of processing step                           
   &01  =  Package number                                   
   &02  =  Name of expert                                   
   &03  =  Component residence                              

Response

Action: Determine cause and answer message with tsn.0/1.      
  TSN.0  The processing step is repeated.                   
  TSN.1  The load procedure aborts. The Enter procedure     
         SOLIS.E.AUS.package must be restarted. The package 
         may have to be reset and regenerated.              
  TSN.2  The error is ignored.                              

SOL0217

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0217     PACKAGE:(&01) FILE SIZE IS BEING OPTIMIZED                   

Meaning

All files of this delivery are compressed to their actual     
size with /FILE file,SPACE=-99999.                          
   &01  =  Package number                                   

Response

Action: none                                                  

SOL0218

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0218   ! (&00) PACKAGE:(&01) ERROR DURING FILE OPTIMIZATION - PLEASE INFORM EXPERT:(&02)                                                     

Meaning

File compression (/FILE file,SPACE=-99999) has been rejected  
with a DMS error. For more information, see the error log.  
   &00  =  No. of processing step                           
   &01  =  Package number                                   
   &02  =  Name of expert                                   

Response

Action: Determine cause and answer message with tsn.0/1.      
  TSN.0  The processing step is repeated.                   
  TSN.1  The load procedure aborts. The Enter procedure     
         SOLIS.E.AUS.package must be restarted. The package 
         may have to be reset and regenerated.              
  TSN.2  The error is ignored.                              

SOL0219

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0219     PACKAGE:(&01) RETPD IS BEING UPDATED                         

Meaning

All files that have already been created within the scope of  
the delivery concerned are given a retention period assigned
in the FMSG parameter STCJ or are deleted if STCJ=00000.    
   &01  =  Package number                                   

Response

Action: none                                                  

SOL0220

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0220   ! PACKAGE:(&01) ERROR DURING RETPD UPDATE                      

Meaning

RETPD updating (see FMSG parameter STCJ) has been rejected    
with a DMS error. The RETPD is not updated.                 
   &01  =  Package number                                   

Response

Action: Determine cause.                                      

SOL0221

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0221   ! (&00) PACKAGE:(&01) LACK OF STORAGE SPACE IN SW DEPOT - PLEASE INFORM EXPERT:(&02)                                                  

Meaning

The storage space (public/private) required for delivery      
(transfer) is not available. For more information, see the  
error log.                                                  
   &00  =  No. of processing step                           
   &01  =  Package number                                   
   &02  =  Name of expert                                   

Response

Action: Determine cause and answer message with tsn.0/1.      
  TSN.0  The processing step is repeated.                   
  TSN.1  The load procedure aborts. The Enter procedure     
         SOLIS.E.AUS.package must be restarted. The package 
         may have to be reset and regenerated.              
  TSN.2  The error is ignored.                              

SOL0300

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0300     LIBRARY (&02) IS EXTENDED BY (&03)                           

Meaning

The (&02) library is merged into the (&03) library.           
&02  =   Output library                                    
&03  =   Input library                                     

Response

Action: none                                                  

SOL0301

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0301   ! (&00) * ERROR IN EXTENSION OF LIBRARY:(&03) - TSN.0=REPEAT, TSN.1=ABORT, TSN.2=IGNORE                                               

Meaning

An error has occurred in the extension of the &01 library.    
The LMR/MLU/LMS/LMSCONV program terminated with TERMJ. For  
more information, see the error log.                        
  &00  =  No. of processing step                            
  &03  =  Output library                                    

Response

Action:                                                       
- TSN.0  Eliminate error and repeat merging process.       
- TSN.1  The job aborts. Regenerate SOLIS.K.package.ishort 
          with /DO A.DO.ishort.package and restart it.      
- TSN.2  The error is ignored and the load procedure       
          continues.        I M P O R T A N T :             
-        Do not delete any temporary files (MSG:SOL0206).  

SOL0302

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0302     PACKAGE:(&01) LIBRARY:(&02) IS BEING GENERATED               

Meaning

The delivery tools required by the customer are stored by LMS 
in the (&03) library.                                       
&01  =   Package number                                    
&02  =   Output library                                    

Response

Action: none                                                  

SOL0303

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0303   ! (&00) PACKAGE:(&01) ERROR IN (&03) GENERATION - PLEASE INFORM EXPERT: (&02)                                                          

Meaning

The (&03) library could not be generated properly. For more   
information, see the error log.                             
   &00  =  No. of processing step                           
   &01  =  Package number                                   
   &02  =  Name of expert                                   
   &03  =  Name of library                                  

Response

Action: Determine cause and answer message with tsn.0/1.      
  TSN.0  The processing step is repeated.                   
  TSN.1  The load procedure aborts. The Enter procedure     
         SOLIS.E.AUS.package must be restarted. The package 
         may have to be reset and regenerated.              
  TSN.2  The error is ignored.                              

SOL0304

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0304   ! IMPORTANT: THE FILE:(&02) MUST BE TRANSFERRED TO THE LIBRARY:(&03) MANUALLY. PLEASE ENTER TSN.                                      

Meaning

The library:(&03) could not be extended. The file:(&02) must  
be merged into the target library manually with the LMS/    
LMSCONV utility. The merge procedure can be performed       
parallel to the load procedure.                             
&02  =   Input library                                     
&03  =   Output library                                    

Response

Action: Enter tsn. - start merge procedure                    

SOL0305

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0305     PACKAGE:(&01) TRANSFER LIBRARY:(&02) IS BEING GENERATED      

Meaning

All files for the (&01) package are stored in the (&02)       
library. The library is transferred with FT-BS2000.         
&01  =   Package number                                    
&02  =   Output library                                    

Response

Action: none                                                  

SOL0306

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0306   ! (&00) PACKAGE:(&01) ERROR IN (&03) GENERATION - PLEASE INFORM EXPERT: (&02)                                                          

Meaning

The (&03) library could not be generated properly. For more   
information, see the error log.                             
   &00  =  No. of processing step                           
   &01  =  Package number                                   
   &02  =  Name of expert                                   
   &03  =  Name of library                                  

Response

Action: Determine cause and answer message with tsn.0/1.      
  TSN.0  The processing step is repeated.                   
  TSN.1  File transfer aborts. The Enter procedure          
         SOLIS.E.BEW.package must be restarted. The delivery
         groups concerned may have to be unlocked (PRODV    
         mask) in SOLIS2 and submission restarted.          
  TSN.2  The error is ignored.                              

SOL0400

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0400     THE (&02) MESSAGE CONTAINER IS BEING EXTENDED                

Meaning

Update of the &02 message file has started.                   
&02  =   Name of message file                              

Response

Action: none                                                  

SOL0401

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0401   ! (&00) * ERROR IN EXTENSION OF (&02) MESSAGE CONTAINER - TSN.0=REPEAT, TSN.1=ABORT, TSN.2=IGNORE                                     

Meaning

Errors have occurred during update of the (&02) message       
container. The MSGLIB utility terminated with TERMJ.        
(Messages are not transferred.)                             

Response

Action:                                                       
  TSN.0 - Message processing is repeated.                   
  TSN.1 - The SOLIS load procedure terminates.              
  TSN.2 - The load procedure continues. The message container
          must be updated manually with the DO.INSTALLATION 
          (FUNCTION:MSG) procedure after delivery integra-  
          tion.                                             

SOL0500

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0500     (&02) PROCEDURE:(&03) HAS STARTED                            

Meaning

The (&02) procedure is called up with /(&02) (&03).           
  &02   =   Type of procedure (DO/ENTER)                    
  &03   =   Name of procedure                               

Response

Action: none                                                  

SOL0501

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0501   ! ERROR DURING INSTALLATION PROCEDURE:(&03) - PLEASE ENTER TSN.

Meaning

The (&03) installation procedure could not be performed       
properly. The installation job can be continued with TSN.   
After the installation job has been logged off, the (&03)   
procedure must be started manually under the TSOS user ID.
   &00  =  No. of processing step                           
   &02  =  Name of installation procedure                   

Response

Action: Enter tsn.                                            

SOL0502

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0502   ! START (&02) PROCEDURE:(&03) MANUALLY - USER ID:(&04)         

Meaning

As the installation was not stored under the installation ID  
specified in the delivery documentation, the (&02) procedure
could not be started automatically. It must first be checked
and, if necessary, adapted to the modified installation     
conditions and then started under the (&02) user ID.        
   &00  =  No. of processing step                           
   &01  =  Package number                                   
   &02  =  Name of procedure                                
   &03  =  Installation ID                                  

Response

Action: Start procedure manually after checking it.           

SOL0510

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0510   IMON REGISTRATION PROCEDURE FOR PACKAGE (&02) STARTED.         

Meaning

Registration of package (&02) for IMON has started.           
&02  =   package name                                      

SOL0511

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0511   IMON REGISTRATION PROCEDURE FOR PACKAGE (&02) ENDED.           

Meaning

Registration of package (&02) for IMON has ended without error.
&02  =   package name                                      

Response

Action: none                                                  

SOL0512

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0512   ! ERROR DURING RUN OF IMON REGISTRATION PROCEDURE FOR PACKAGE (&02). ENTER TSN.

Meaning

The IMON Registration procedure for package (&02) terminated  
with error. The load procedure can be continued with TSN.   
After the load procedure has been logged off, the registra- 
tion must be started manually under $TSOS, when the problem 
is solved. Name of procedure = SOLPRC.REG.IMON.<package>    
   &02  =  package name                                     

Response

Action: enter tsn.                                            

SOL0513

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0513   ! THE IMON-REGISTRATION MUST BE STARTED MANUALLY AFTER CLEARING OF THE PROBLEMS !      PROCEDURE = (&02)     ENTER TSN.               

Meaning

The IMON registration will not start automatically because    
the load procedure has been terminated with warning / error.
After solving the problems, the registration must be started
manually by calling the procedure (&02) under $TSOS.        

Response

Action: enter tsn.                                            

SOL0600

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0600     INTEGRATION OF (&02) RMS DELIVERY SET HAS STARTED            

Meaning

Integration of the (&02) RMS delivery set into the RMS depot  
has started.                                                
   &02  =  File name of the RMS delivery set                

Response

Action: none                                                  

SOL0601

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0601   ! (&00) * ERROR DURING INTEGRATION OF RMS DELIVERY SET (&02) - TSN. 0=REPEAT, TSN.1=ABORT, TSN.2=IGNORE                                

Meaning

An error has occurred during integration of the &02 RMS       
delivery set. Important: RMS delivery sets are treated like 
temporary files with respect to SOLIS2. This must be taken  
into account when answering the SOL0206 message.            
   &00  =  No. of processing step                           
   &02  =  File name of RMS delivery set                    

Response

Action:                                                       
The cause of the error can be determined with the RMS log   
(file name SOLIS.L.RMS.package).                            
  -   TSN.0  The installation step is repeated.             
  -   TSN.1  The load procedure aborts and must be restarted
             after error elimination.                       
  -   TSN.2  The error is ignored.                          

SOL0602

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0602     REP LOADER GENERATION FROM RMS DEPOT HAS STARTED             

Meaning

All REP loaders marked in the RMS depot for loader setup are  
generated.                                                  

Response

Action: none                                                  

SOL0603

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0603   ! (&00) * ERROR IN RMS PROCESSING (SEE:(&02)) - ENTER TSN.1=ABORT, TSN. 2=IGNORE                                                       

Meaning

An error has occurred during loader generation with RMS.      
For more information, see the RMS log (&02). Important: Not 
all loaders required for product use have been generated!   
   &00  =  No. of processing step                           
   &02  =  File name of RMS log                             

Response

Action:                                                       
  -   TSN.1  The load procedure aborts and must be restarted
             with (/DO A.DO.ishort.package or               
             /E SOLIS.K.pack.ishort) after error elimination.
  -   TSN.2  The error is ignored.                          

SOL0604

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0604     * RMS DELIVERY SET:(&02) PROVIDED                            

Meaning

You have answered the prompt concerning the processing of RMS 
delivery sets with N or TERM. As a result, the RMS file by  
the delivery name (&02) is not deleted (it can be integrated
manually into the desired RMS depot).                       

Response

Action: Integrate RMS file into the depot manually.           

SOL0700

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0700     SYNTAX FILE (&02) IS BEING EXTENDED                          

Meaning

The &02 syntax file is extended with the SDF-I program.       
  &02  =   Name of syntax file                              

Response

Action: none                                                  

SOL0701

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0701   ! SDF-I TERMINATED WITH WARNINGS (FILE:(&02)). ENTER TSN.

Meaning

The SDF-I utility has terminated with warnings.               
This may be due to a faulty syntax type or MERGE statement. 
The SOLIS.package.WORKOUT syntax file created by SDF-I is   
copied to &02 and then deleted.                             
  &02  =  Syntax container                                  

Response

Action:                                                       
   -   Enter TSN.                                           
       After delivery integration, check the SYSOUT log and 
       subsequently merge in missing syntax files.          

SOL0702

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0702   ! (&00) * ERROR IN EXTENSION OF SYNTAX FILE (&02) - TSN.0=REPEAT, TSN. 1=ABORT, TSN.2=IGNORE                                           

Meaning

An error has occurred during syntax file processing. This may 
be due to an error when merging with SDF-I or to the fact   
that syntax files could not be copied properly for submission
or processing for the SDF-I program.                        
   &00  =  No. of processing step                           
   &02  =  File name of syntax file                         

Response

Action:                                                       
  -   TSN.0  The installation step is repeated.             
  -   TSN.1  The load procedure aborts and must be restarted
             with (/DO A.DO.ishort.package or               
             /E SOLIS.K.pack.ishort) after error elimination.
  -   TSN.2  The error is ignored.                          

SOL0703

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0703     SYNTAX FILE (&02) IS BEING ACTIVATED                         

Meaning

The newly created &02 syntax file is activated in the current 
session.                                                    
   &02  =  Name of syntax file                              

Response

Action: none                                                  

SOL0704

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0704   ! (&00) * ERROR DURING ACTIVATION OF SYNTAX FILE (&02) - TSN.0=REPEAT, TSN. 1=ABORT, TSN.2=IGNORE                                      

Meaning

An error has occurred during activation of the &02 syntax file.
The /MODIFY-SDF-PARAMETERS command could not be performed properly.
The syntax files are checked with SDF-U if they contain the LOGON-
command (SYSTEM-SYNTAX) or the MODIFY-SDF-PARAMETERS command
(GROUP.TSOS). If these requirements are fulfilled, the syntax file
are assigned in the system.
   &00  =  No. of processing step                           
   &02  =  Name of syntax file                              

Response

Action:                                                       
  -   TSN.0  Activation is restarted.                       
  -   TSN.1  The load procedure aborts. The procedure       
             A.DO.ishort.package must be restarted.         
  -   TSN.2  The error is ignored and must be eliminated    
             manually (command /MODIFY-SDF-PARAMETERS or /ADD-USER).
  -          IMPORTANT: SYSTEM-READY is not possible without
             SDF. Please check the SDF parameter file!

SOL0705

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0705     SDF PARAMETER FILE (&02) IS COPIED TO (&03)                  

Meaning

The Message is given only when changing SDF. From the         
next startup the file (&03) will be used to perform syntax  
analysis.                                                   
   &02  =  Name of old SDF parameter file                   
   &03  =  Name of new SDF parameter file                   

Response

Action: none                                                  

SOL0706

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0706   ! (&00) * COPY OF SDF PARAMETER FILE:(&02) TO (&03) FAILED - TSN.0=REPEAT TSN.1=ABORT TSN.2=IGNORE

Meaning

The file (&02) could not be copied to (&03).                  
Cause: see the error log                                    
Clear fault before entering tsn.2 !!!!                      
   &00  =  No. of processing step                           
   &02  =  Name of old SDF parameter file                   
   &03  =  Name of new SDF parameter file                   

Response

Action:                                                       
  -   TSN.0  Copy is retried.                               
  -   TSN.1  Abort of procedure. A.DO.ishort.package is to  
             be started anew.                               
  -   TSN.2  Continue with tsn.2 only if fault has been     
             cleared before.                                
  -          Attention: SYSTEM READY is not possible without
             SDF. Please check the file (&02) or (&03) !

SOL0707

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0707   * SDF-A IN USE

Meaning

In the current System the utility programm SDF-A is installed.
This has been checked with /SHOW-FILE-ATTRIBUTES $SDF-A

Response

Action:                                                       
If you had made changes within the syntax files the system  
uses, you will have to perform the same changes after the   
current installation.                                       
(e.g. SYS.SDF.SYSTEM.SYNTAX, SYS.SDF.GROUP.SYNTAX.TSOS)     
Please response on this message with tsn.                   

SOL0708

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0708     SDF PARAMETER FILE (&02) WILL BE USED.                       

Meaning

This file will be updated after correct run of SDF-I          
   &02  =  Name of the SDF parameter file                   

Response

Action: none                                                  

SOL0709

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0709   ! (&00) * /MODIFY-FILE-ATTRIBUTES COMMAND FOR SDF PARAMETER FILE (&02) FAILED - TSN.0=REPEAT TSN.1=ABORT TSN.2=IGNORE

Meaning

The file (&02) could not be cataloged to ACCESS=WRITE
Cause: see the error log
Clear fault before entering tsn.2 !!!!
   &00  =  No. of processing step    
   &02  =  Name of SDF parameter file

Response

Action:
  -   TSN.0  /MODIFY-FILE-ATTRIBUTES is retried.
  -   TSN.1  Abort of procedure. A.DO.ishort.package is to
             be started anew.
  -   TSN.2  Continue with tsn.2 only if fault has been
             cleared before.
  -          Attention: SYSTEM READY is not possible without
             SDF. Please check the file (&02) !

SOL0710

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0710     SYNTAXFILE (&02) WILL BE CHECKED.                            

Meaning

The completeness of this file will be checked by SOLIS2.      
   &02  =  Name of syntaxfile to be checked.                

Response

Action: none                                                  

SOL0711

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0711   ! (&00) * ERROR DETECTED AT CHECKING OF SYNTAXFILE (&02) - TSN.0=REPEAT TSN.1=ABORT TSN.2=IGNORE

Meaning

Error detected at completeness-check of syntaxfile (&02)      
Cause: The checked syntaxfile is not complete and thus not  
usable for the system-STARTUP. The checked file contains no 
/LOGON command (if SYSTEM-syntaxfile), no /MODIFY-SDF-PARAMETERS
command (if GROUP-syntaxfile).                              

Response

Action:                                                       
  -   TSN.0  Checking is retried.                           
  -   TSN.1  Abort of procedure. A.DO.ishort.package is to  
             be started anew.                               
  -   TSN.2  Continue with tsn.2 only if fault has been     
             cleared before.                                
  -          Attention: SYSTEM READY is not possible without
             SDF. Please check the file (&02) !

SOL0800

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0800     DSSM GENERATION FILE (&02) IS BEING EXTENDED                 

Meaning

The &02 DSSM generation file is being modified. All delivery  
components marked with DSM in the delivery cover letter are 
transferred to the generation file or modified, depending on
the hardware configuration.                                 
  &02   =   Name of DSSM generation file                    
            Default name = $TSOS.SYS.SSD.DSSM(.X)           

Response

Action: none                                                  

SOL0801

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0801   ! (&00) * EXTENSION OF DSSM GENERATION FILE (&02) TERMINATED WITH WARNINGS - TSN.0=REPEAT TSN.1=ABORT TSN.2=IGNORE                    

Meaning

The DSSM generation file could not be extended properly.      
The following may have caused this situation:               
   - own declaration statements exist                       
   - individual declaration files not cataloged             
  &00   =   Number of processing step                       
  &02   =   Name of subsystem declaration file              

Response

Action:                                                       
  -   TSN.0  The installation step is repeated.             
  -   TSN.1  The loead procedure aborts and must be restarted
             with (DO A.DO.ishort.package or                
             /E SOLIS.K.pack.ishort) after error elimination.
  -   TSN.2  The error is ignored.                          

SOL0802

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0802   ! (&00) * ERROR IN EXTENSION OF DSSM GENERATION FILE (&02) - TSN.0=REPEAT, TSN.1=ABORT, TSN.2=IGNORE                                  

Meaning

An error has occurred during modification of the &02 DSSM     
generation file. The subsystem catalog cannot be updated.   
   &00  =  No. of processing step                           
   &02  =  Name of DSSM generation file                     
           Default name = $TSOS.SYS.SSD.DSSM(.X)            

Response

Action:                                                       
  -   TSN.0  The installation step is repeated.             
  -   TSN.1  The load procedure aborts and must be restarted
             with (/DO A.DO.ishort.package or               
             /E SOLIS.K.pack.ishort) after error elimination.
  -   TSN.2  The error is ignored.                          

SOL0803

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0803     SUBSYSTEM CATALOG (&02) IS BEING GENERATED                   

Meaning

  &02   =   Name of subsystem catalog                         
            Default name = $TSOS.SYS.SSD.CAT(.X)            

Response

Action: none                                                  

SOL0804

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0804   ! (&00) * ERROR IN GENERATION OF SUBSYSTEM CATALOG (&02) - TSN.0=REPEAT, TSN.1=ABORT, TSN.2=IGNORE                                    

Meaning

An error has occurred during extension of the &02 subsystem   
catalog. The previously used catalog is saved.              
   &00  =  No. of processing step                           
   &02  =  Name of subsystem catalog                        
           Default name = $TSOS.SYS.SSD.CAT(.X)             

Response

Action:                                                       
  -   TSN.0  The installation step is repeated.             
  -   TSN.1  The load procedure aborts and must be restarted
             with /CALL-PROC A.DO.ishort.package or               
             /ENTER-JOB SOLIS.K.pack.ishort after error elimination.
  -   TSN.2  The error is ignored. The subsystem catalog must
             be generated manually by SSCM after error elimination.

SOL0805

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0805     CURRENT SUBSYSTEM CATALOG IS BEING SAVED UNDER (&02)         

Meaning

The subsystem catalog currently being used is saved under     
(&02) and the original file is deleted.                     
   &02  =  File name of saved subsystem catalog             

Response

Action: none                                                  

SOL0905

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0905   ! (&00) * REPFILE GENERATION (RESULT) FOR SU:(&02) FAULTY - TSN.0=REPEAT TSN.1=ABORT TSN.2=IGNORE

Meaning

During generation of repfiles with the utility RESULT an error
occured. The repfile for SU:(&00) could not be generated.   
The previous repfile has been saved in the userid SYSSAG    
under its original name.                                    
   &00  =  Nr. of processing step                           
   &02  =  Name of selectable unit                          

Response

Action:                                                       
  -   TSN.0  Repeat installation step                       
  -   TSN.1  The load procedure aborts and must be          
             restarted with (/DO A.DO.ishort.package or     
             /E SOLIS.K.pack.ishort) after error elimination.
  -   TSN.2  The error is ignored. After installation the   
             repfile is to be generated manually with the   
             procedure DO.INSTALLATION (FKT:REP).           

SOL0908

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0908     ATTENTION !!! PLEASE CREATE SVL ANEW IMMEDIATELY !!!         

Meaning

Boot loader files have been overwritten. SVL chaining may be  
destroyed. In this case BS2000 startup would faile !!!      

Response

Action:                                                       
Chaine SVL files anew with following procedure call:        
             /DO DO.INSTALLATION,FKT=SVL                    
Only after successful chaining enter tsn. to continue the   
installation process.                                       

SOL0918

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0918     REPFILE GENERATION (RESULT) FOR SU: (&02) STARTED            

Meaning

The utility RESULT generates the repfile for selectable unit =
&02                                                         
&02  =   Name of selectable unit                           

Response

Action: none                                                  

SOL0941

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0941     FILE (&02) IS BEING CREATED - SOURCE: (&03)                  

SOL0942

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0942   ! (&00) * ERROR IN CREATION OF FILE (&02) - TSN.0=REPEAT TSN.1=ABORT TSN. 2=IGNORE

Meaning

An error has occured by creation of file (&02)                
For more information see error log.                         
  &00  =  Nr. of processing step
  &02  =  filename

Response

action: none                                                  
  -   TSN.0  eliminate error and repeat installation-step   
  -   TSN.1  the process aborts. Restart installation with  
             /CALL-PROC A.DO.kkz.paket or
             /ENTER-JOB SOLIS.K.paket.kkz after error elimination.
  -   TSN.2  error is ignored                               

SOL0948

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0948     EXTENDING REPFILES LOGGING FILE (&02)                        

Meaning

New selectable units or optional reps are added to repfiles   
logging file &02.                                           
  &02   =   Name of repfiles logging file                   
            Standard name = $TSOS.RESULT.INFOFILE           

Response

Action: none                                                  

SOL0949

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0949   ! (&00) * EXTENTION OF FILE (&02) FAULTY - TSN.0=REPEAT TSN.1=ABORT TSN. 2=IGNORE                                                      

Meaning

Error during update of repfiles logging file. Check protocol  
for further information.                                    
   &00  =   Nr. of process step                             
   &02  =   Name of repfiles logging file                   
            Standard name = $TSOS.RESULT.INFOFILE           

Response

Action:                                                       
  -   TSN.0  Repeat installation step.                      
  -   TSN.1  The load procedure aborts and must be          
             restarted with (/DO A.DO.ishort.package or     
             /E SOLIS.K.pack.ishort) after error elimination.
  -   TSN.2  The error is ignored.                          

SOL0955

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0955     EXTENTION OF REFERENCE FILE (&02)                            

Meaning

In file &02 the files of delivery are logged                  
   &02  =  Name of reference file                           
           The file is a relation directory between products
           and file names.                                  

Response

Action: none                                                  

SOL0956

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0956   ! FAULT DURING UPDATE OF REFERENCE FILE (&02) - TSN.0=REPEAT, TSN.1=ABORT, TSN.2=IGNORE

Meaning

The reference file could not be updated properly              
   &02  =  Name of reference file                           
           The file is a relation directory between products
           and file names.                                  

Response

Actions: Determine cause, solve the problem if possible and
         answer with:                                      
  TSN.0  The processing step is repeated.                   
  TSN.1  The processing of the reference file is skipped.   
         Please inform your support-center partner.     
  TSN.2  The error is ignored.                              
  Hint:  Check for lock on reference file (PRINT-LOCK)      

SOL0970

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0970   ! PACKAGE:(&01) FAULT ON TRANSMITTAL OF DELIVERY INFORMATION   

Meaning

The delivery information has not been properly transmitted to 
the SD-RZ. The message is to be answered with TSN. Check the
cause of the error with the protocol SOLIS.L.GL.paket.uhr   
   &01  =  package name                                     

Response

Action: enter TSN. and check protocol.                        

SOL0997

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0997   ! FILE (&01) HAS BEEN UPDATED IN REFERENCE FILE                

SOL0998

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL0998   ! FILE (&01) HAS BEEN ERASED IN REFERENCE FILE                 

SOL1500

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1500   ERROR (&00) AT CMD-CALL: SYNTAX !                              

SOL1501

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1501   RDATA-ERROR IN W2GEN                                           

SOL1502

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1502   NO OUTPUT FILE OPENED !                                        

SOL1503

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1503   WRLST SHORTENED TO PRINT LENGTH !                              

SOL1504

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1504   COMMAND/PATTERN PROCEDURE UNKNOWN !                            

SOL1505

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1505   ERROR (&00) AT OPENING OF MOVEMENT FILE / PATTERN PROCEDURE    

SOL1506

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1506   FILE-MACRO-ERROR: (&00)                                        

SOL1507

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1507   WRONG PATTERN PROCEDURE NAME OR ALREADY EXISTING !             

SOL1508

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1508   TERMJ IN AUSGEN !                                              

SOL1509

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1509   ONLY "ON" OR "OFF" PERMITTED !                                 

SOL1510

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1510   GET COMMAND WITHOUT FILE NAME !                                

SOL1511

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1511   ONLY 3 LEVEL GET INTERLEAVING POSSIBLE !                       

SOL1512

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1512   ERROR AT MACRO CALL UP CMD (&00)                               

SOL1513

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1513   ERROR AT CLOSING OF FILE; OPEN MISSING                         

SOL1514

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1514   OPEN COMMAND SYNTACTICALLY WRONG !                             

SOL1515

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1515   JUMP TARGET '(&00)' NOT FOUND !                              

SOL1516

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1516   LOOP: NOT IN HIERARCHIE !                                      

SOL1517

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1517   FOR: SECOND PARAMETER INVALID !                                

SOL1518

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1518   FOR NOT ACCORDING TO HIERARCHIE !                              

SOL1519

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1519   AT READ 2. PARAMETER WRONG !                                   

SOL1520

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1520   LOOP: SECOND PARAMETER INVALID !                               

SOL1521

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1521   CORRESPONDING *END RESP. *NEXT NOT WITHIN THE PATTERN PROCEDURE

SOL1522

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1522   GOTO IN *IF-COMMAND WRONG OR MISSING !                         

SOL1523

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1523   PARTNAME WRONG OR ALREADY PRESENT !                            

SOL1524

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1524   CREATE: SYNTAX WRONG !                                         

SOL1525

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1525   SUBPART STRING MISSING !                                       

SOL1526

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1526   PUT: SYNTAX WRONG !                                            

SOL1527

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1527   PARTNAME WRONG OR PART NOT PRESENT !                           

SOL1528

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1528   JUMP TARGET INDICATION MISSING/NOT NUMERIC !                   

SOL1529

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1529   STRING > 80, FIRST 80 ARE USED !                               

SOL1530

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1530   SET: PARAMETER MISSING !                                       

SOL1531

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1531   SET: PARAMETER NOT APPLICABLE !                                

SOL1532

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1532   PARAMETER TOO LONG, MAX. LENGTH 12 !                           

SOL1533

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1533   INPUT TOO LONG, MAX. 12 !                                      

SOL1534

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1534   WRTRD CMD ERROR !                                              

SOL1535

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1535   TEXT MISSING IN WRTRD COMMAND !                                

SOL1536

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1536   IF: 1. PARAMETER WRONG !                                       

SOL1537

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1537   IF: COMPARISON CODE WRONG !                                    

SOL1538

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1538   IF: 2. COMPARISON PARAMETER WRONG !                            

SOL1539

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1539   ERROR MESSAGE NUMBER NOT AVAILABLE                             

SOL1540

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1540   PARTNAME INVALID !                                             

SOL1541

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1541   NO ELEMENT RECORD READ BEFORE *ADD !                           

SOL1542

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1542   T: PRIORITY/LINE FEED WRONG !                                  

SOL1543

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1543   T: TEXT TOO LONG (MAX. 124) !                                  

SOL1544

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1544   BOPEN: FILE NAME/PVD MISSING !                                 

SOL1545

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1545   ERROR AT OPENING OF MOVEMENT / PRODUCT ADMINISTRATION FILE

Meaning

Possible reasons:                                             
- password protection, retention period, read access (rc: 37)
- wrong file format (rc: 39)                                

Response

Please contact SOLIS administrator.                           

SOL1546

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1546   PBD: NOT PRESENT/WRONG !                                       

SOL1547

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1547   ERROR (&00) AT FILE (&01) !                                    

SOL1548

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1548   FSTAT: NAME MISSING/PARTLY QUALIFIED !                         

SOL1549

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1549   FMSG: KEY INDICATION MISSING !                                 

SOL1550

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1550   KEY (&00) NOT IN FMSG FILE !                                   

SOL1551

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1551   SELUID: FILE NAME WRONG !                                      

SOL1552

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1552   PUT IN FOR-LOOP NOT PERMITTED !                                

SOL1553

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1553   UNKNOWN SYMB. PARAMETER !                                      

SOL1554

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1554   INCR: PARAMETER NOT NUMERIC !                                  

SOL1555

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1555   INCR-/INCB-BY CLAUSE WRONG !                                   

SOL1556

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1556   FSTAT: MORE THAN 1 FILE FOUND                                  

SOL1557

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1557   FSTAT: NO FILE FOUND                                           

SOL1558

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1558   COMMAND NOT ALLOWED FOR BD !                                   

SOL1559

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1559   READ AND NO MF-RECORD READ !                                   

SOL1560

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1560   *READ PVDKOMP AND NO SG-/SC-RECORD READ !                      

SOL1561

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1561   FOR LF-RECORD (&01) SG-RECORD (&02) DELETED !                  

SOL1562

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1562   PUTX: FOR SC RECORD NOT IN LOOP KOMPS !                        

SOL1563

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1563   ACCESS ERROR ON MF !                                           

SOL1564

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1564   UNLOCK: SG RECORD NOT READ WITH *READ PVDPROD !                

SOL1565

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1565   UNLOCK: PRODUCT NOT LOCKED !                                   

SOL1566

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1566   GETKY: KEY NOT (&00) DIGITS !                                  

SOL1567

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1567   DEFVAR: NAME TOO LONG OR NOT ZV... !                           

SOL1568

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1568   DEFVAR: NAMES NOT ASCENDING !                                  

SOL1569

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1569   DEFVAR: LENGTH NOT NUMERIC OR > 11 !                           

SOL1570

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1570   DEFVAR: TOO MANY ENTRIES !                                     

SOL1571

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1571   ERROR AT ACCESS FROM DB (&00) !                                

SOL1572

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1572   SETB: INPUT IS NEGATIVE !                                      

SOL1573

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1573   BOPTA: PERMITTED ONLY FOR PVD !                                

SOL1574

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1574   -LSNR- NOT PERMITTED DURING -BOPTA-                            

SOL1575

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1575   -BOPEN- WITHOUT -BCLOSE- !                                     

SOL1576

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1576   *READ PVDSTRU AND NO SG-/SC-RECORD READ !                      

SOL1577

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1577   FREE                                                           

SOL1578

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1578   FREE                                                           

SOL1579

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1579   FREE                                                           

SOL1580

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1580   RECORD TO BE DELETED NOT IN PVD !                              

SOL1581

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1581   MOD: WRONG OR ALREADY PRESENT !                                

SOL1582

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1582   MOD ROUTINE NOT PRESENT !                                      

SOL1583

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1583   ## MUST BE FOLLOWED BY MOD NAME !                              

SOL1584

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1584   WRONG INPUT IN FIELD MODNAME                                   

SOL1585

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1585   MOD EXTENTION NOT AN ALPHA CHARACTER !                         

SOL1586

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1586   WRLST-ERROR: RECORD TRUNCATED !                                

SOL1587

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1587   WRLST-ERROR: NO MORE SPACE AVAILABLE !                         

SOL1588

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1588   WRLST-ERROR: UNRECOVERABLE ERROR !                             

SOL1600

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1600   FREE                                                           

SOL1700

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1700   FREE                                                           

SOL1701

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1701   ERROR (&00) AT OPEN OF MOVEMENT FILE (&01)                     

SOL1702

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1702   ERROR IN NAM-STATEMENT (&00)                                   

SOL1703

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1703   ERROR AT OPEN OF LOGICAL FILE (&00)                            

SOL1704

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1704   ERROR AT BEGIN OF TRANSACTION (&00)                            

SOL1705

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1705   ERROR AT CLOSE/RESET TRANSACTION (&00)                         

SOL1706

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1706   ERROR AT READ OF DB-HEADER-RECORD (&00)                        

SOL1707

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1707   ERROR AT WRITE OF DB-HEADER-RECORD (&00)                       

SOL1708

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1708   ERROR AT READ OF SU RECORD (&00)                               

SOL1709

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1709   ERROR AT WRITE SU RECORD (&00)                                 

SOL1710

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1710   FREE                                                           

SOL1711

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1711   ERROR AT READ SG RECORD (&00)                                  

SOL1712

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1712   ERROR AT WRITE SG RECORD (&00)                                 

SOL1713

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1713   FREE                                                           

SOL1714

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1714   SG NOT IN DATA BASE (&00)                                      

SOL1716

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1716   ERROR AT READ SC RECORD (&00)                                  

SOL1717

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1717   ERROR AT WRITE SC RECORD (&00)                                 

SOL1718

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1718   ERROR AT READ CR RECORD (&00)                                  

SOL1719

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1719   ERROR AT WRITE CR RECORD (&00)                                 

SOL1720

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1720   ERROR AT READ OF TEXT RECORD (&00)                             

SOL1721

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1721   ERROR AT WRITE TEXT-RECORD (&00)                               

SOL1722

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1722   ERROR AT DELETE OF TEXT RECORD (&00)                           

SOL1723

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1723   ERROR AT OPEN OF TDS-FILE                                      

SOL1724

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1724   ERROR AT READ OF TDS RECORD (&00)                              

SOL1725

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1725   ERROR AT WRITE TDS-RECORD (&00)                                

SOL1726

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1726   FREE                                                           

SOL1727

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1727   FREE                                                           

SOL1728

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1728   ERROR AT READ OF LF-RECORD (&00)                               

SOL1729

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1729   ERROR AT WRITE LF-RECORD (&00)                                 

SOL1730

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1730   MEDIUM RECORD MISSING (&00)                                    

SOL1731

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1731   ERROR AT CLOSE STATEMENT                                       

SOL1732

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1732   SU LOCKED (&00)                                                

SOL1733

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1733   SG LOCKED (&00)                                                

SOL1734

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1734   ERROR AT READ OF ELEMENT RECORD (&00)                          

SOL1735

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1735   ERROR AT WRITE ELEMENT-RECORD (&00)                            

SOL1736

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1736   ERROR AT DELETE OF ELEMENT RECORD (&00)                        

SOL1737

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL1737   SG (&00) BELONGS TO MORE THAN (&01) SU                         

SOL3100

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3100   (&00) RECORDS TRUNCATED                                        

SOL3101

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3101   MAXIMUM NUMBER OF TEXT RECORDS REACHED (&00) !                 

SOL3102

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3102   BS2000 FILE WRITTEN !

SOL3103

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3103   BREAK: TRANSACTION WILL BE RESET !                             

SOL3104

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3104   TRANSACTION RESET !                                            

SOL3105

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3105   NO MOVEMENT FOR ANY SG !

SOL3106

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3106   THE SG WILL BE DELETED !                                       

SOL3107

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3107   ATTENTION: FURTHER SC WILL BE ADDED WITHOUT CHECK !            

SOL3108

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3108   SC WITH THIS VERSION PRESENT MORE THAN ONCE !                  

SOL3109

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3109   ONLY THE LAST SELECTION WILL BE DONE !                         

SOL3110

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3110   SUPPLY GROUP UNLOCKED !                                        

SOL3111

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3111   ENTER DATA FOR NEW SG (UNDERLINED) !                           

SOL3112

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3112   SC PROCESSING WAS PASSED OVER !                                

SOL3113

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3113   ARE THE REMAINING SG DATA CAPTURED ?                           

SOL3114

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3114   RELEASE ERROR (&00) ON PASSWORD !                              

SOL3115

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3115   BREAK FOR ELEMENT PROCESSING                                   

SOL3116

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3116   CHANGE CORRECTION TEXT, SUSPENSION !                           

SOL3117

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3117   PRINTOUT GENERATED AND STARTED !                               

SOL3118

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3118   PLEASE ENTER NEXT   V S N                                      

SOL3119

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3119   (&00) PP ARE TO BE SECURED: YES=DUE , NO=B                     

SOL3120

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3120   INSTALLATION FILE NAME > 38 BYTE                               

SOL3121

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3121   MOVEMENT CANCELLED !

SOL3122

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3122   KDCSIGN ACCEPTED !                                             

SOL3123

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3123   NO SC WITH INST-UID (&00) !                                    

SOL3124

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3124   NOT ALL SC WITH INST-UID (&00) !                               

SOL3125

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3125   END OF OUTPUT                                                  

SOL3126

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3126   THE SU WAS NOT DUPLICATED                                      

SOL3127

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3127   DELETION OF MOD ROUTINE OK                                     

SOL3128

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3128   BS2000 FILE GENERATED                                          

SOL3129

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3129   ACQUISITION / CHANGE OF MOD ROUTINE OK                         

SOL3130

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3130   EMPTY MOD ROUTINE IGNORED RESP. DELETED                        

SOL3131

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3131   NO DELETION: MOD ROUTINE NOT IN FMSG !                         

SOL3132

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3132   ACTION CARRIED OUT                                             

SOL3133

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3133   ACTION (&00) TERMINATED                                        

SOL3134

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3134   INDICATED PARAMETER NOT AVAILABLE IN FMSG : (&00)              

SOL3135

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3135   NEW ENTRY !                                                    

SOL3136

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3136   PARAMETER DELETED FROM FMSG FILE : (&00)                       

SOL3137

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3137   PARAMETER NEWLY TAKEN ON IN FMSG FILE : (&00)                  

SOL3138

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3138   INSTALLATION ID NUMBER LIMITED TO 100 !                        

SOL3139

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3139   NO SU FOUND TO THIS SUPPLY TYPE !                              

SOL3140

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3140   SALES PRODUCTS NOT IN PVD RESP. LOCKED !                       

SOL3141

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3141   END OF PAGING REACHED !                                        

SOL3142

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3142   START OF PAGING REACHED !                                      

SOL3143

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3143   NO TEXTS FOR ABH PRESENT !                                     

SOL3144

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3144   NO VALID DEVICE TYPE PRESENT !                                 

SOL3145

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3145   NO INSTALLATION FOUND FOR THIS SUPPLY TYPE !                   

SOL3146

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3146   CURRENT PACKET NAME : (&00)                                    

SOL3147

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3147   ACCESS NOT POSSIBLE AT PRESENT: ERROR (&00) !                  

SOL3148

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3148   FREE                                                           

SOL3149

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3149   PACKET RECORDS MARKED !                                        

SOL3150

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3150   PAKET RECORD DELETED !                                         

SOL3151

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3151   LIMIT OF MODIFICATION ROUTINES IN FMSG IS 100 !                

SOL3152

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3152   FREE                                                           

SOL3153

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3153   ENTER PROCEDURE (&00) STARTED !                                

SOL3154

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3154   ENTER PROCEDURE (&00) GENERATED !                              

SOL3155

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3155   ENTER PROCEDURE (&00) STARTED. MOVEMENT NOT COMPLETLY CARRIED OUT !                                                                   

Meaning

Capacity of tape exhausted !                                  

Response

Action: Carry out generated movement and start sequence BEWE  
      once more !                                           

SOL3156

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3156   ENTER PROCEDURE (&00) GENERATED. MOVEMENT NOT COMPLETLY CARRIED OUT !                                                                 

Meaning

Capacity of tape exhausted !                                  

Response

Action: Carry out generated movement and start sequence BEWE  
      once more !                                           

SOL3157

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3157   FREE                                                           

SOL3158

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3158   SC (&00) NOT SET UP COMPLETELY                                 

SOL3159

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3159   TARGET ID DOES NOT MATCH DELIVERY GROUP                        

SOL3160

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3160    PROTOCOL  SOFTWARE-DELIVERY      DEL. TYPE:          PAGE     

SOL3161

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3161   RESPONSE  :                                                    

SOL3162

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3162   FORW.ROUTE:                                  DELIV. DATE :     

SOL3163

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3163   CUSTOMER SELECTION                                             

SOL3164

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3164   ISHORT    :                                                    

SOL3165

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3165   SELECT  ISHORT    :             -->  DISPO-NR:             ISHORT

SOL3166

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3166   SU/SP:                        V          DATE                  

SOL3167

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3167    SG  :                           V                             

SOL3168

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3168      SC:                                                         

SOL3169

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3169   REMARK   : SP NOT IN DB                                        

SOL3170

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3170   REMARK   : DEP. DELIVERED                                      

SOL3171

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3171   REMARK   : DEP. NOT DELIVERED                                  

SOL3172

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3172   REMARK   : LOCKED                                              

SOL3173

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3173   REMARK   : SU LOCKED (NEW)                                     

SOL3174

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3174   REMARK   : LOCKED (NEW)                                        

SOL3175

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3175   REMARK   : ONLY DEL. NOTE                                      

SOL3176

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3176   REMARK   : NO SUPPLY                                           

SOL3177

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3177   ERROR        :   NO SUPPLY UNIT FOUND                          

SOL3178

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3178    SELECT SUPPLY UNITS                                           

SOL3179

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3179   TYPE OF MEDIUM  :       PACK.NAME:                             

SOL3180

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3180   NO OF CUSTOMER:       NO OF DUPLICATES:       PAM-PAGES:       

SOL3181

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3181   PACK.                                                          

SOL3182

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3182   DM-UTILIZATION:                                                

SOL3183

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3183   CORRECTION PROCESSING WAS PASSED OVER !                        

SOL3200

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3200   FREE                                                           

SOL3201

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3201   NEW FUNCTIONS:   /  - ADAPTION AND PROCESSING OF MORE THAN 150  /    SOFTWARE GROUPS           

SOL3202

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3202     - ADAPTION WITH SHARED PUBSET                /                                               /  -                              

SOL3203

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3203                                    

SOL3204

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3204       DETAILS TO BE FOUND IN RELEASE NOTICE./                     

SOL3205

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3205   FREE                                                           

SOL3206

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3206   FREE                                                           

SOL3207

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3207   FREE                                                           

SOL3208

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3208   FREE                                                           

SOL3209

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3209   FREE                                                           

SOL3210

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3210   FREE                                                           

SOL3211

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3211   FREE                                                           

SOL3212

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3212   FREE                                                           

SOL3213

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3213   FREE                                                           

SOL3214

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3214   FREE                                                           

SOL3215

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3215   FREE                                                           

SOL3216

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3216   FREE                                                           

SOL3217

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3217   FREE                                                           

SOL3218

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3218   FREE                                                           

SOL3219

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3219   FREE                                                           

SOL3220

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3220   FREE                                                           

SOL3221

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3221   FREE                                                           

SOL3222

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3222   FREE                                                           

SOL3223

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3223   FREE                                                           

SOL3224

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3224   FREE                                                           

SOL3225

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3225   FREE                                                           

SOL3226

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3226   FREE                                                           

SOL3227

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3227   FREE                                                           

SOL3228

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3228   FREE                                                           

SOL3229

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3229   FREE                                                           

SOL3230

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3230   FREE                                                           

SOL3231

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3231   FREE                                                           

SOL3232

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3232   FREE                                                           

SOL3233

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3233   FREE                                                           

SOL3234

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3234   FREE                                                           

SOL3235

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3235   FREE                                                           

SOL3236

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3236   FREE                                                           

SOL3237

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3237   FREE                                                           

SOL3238

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3238   FREE                                                           

SOL3239

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3239   FREE                                                           

SOL3240

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3240   SG                                                             

SOL3241

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3241   SC                                                             

SOL3242

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3242   CR                                                             

SOL3243

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3243   SU                                                             

SOL3244

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3244   FREE                                                           

SOL3245

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3245   FREE                                                           

SOL3246

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3246   FREE                                                           

SOL3247

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3247   FREE                                                           

SOL3248

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3248   1                                                              

SOL3249

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3249   2                                                              

SOL3250

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3250   3                                                              

SOL3251

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3251   4-CENTER                                                       

SOL3252

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3252   5-REGION                                                       

SOL3253

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3253   6-CUSTOMER                                                     

SOL3254

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3254   7-DEPEND.                                                      

SOL3255

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3255   ELEMENTS                                                       

SOL3256

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3256   FREE                                                           

SOL3258

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3258   FREE                                                           

SOL3259

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3259   FREE                                                           

SOL3260

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3260   FREE                                                           

SOL3261

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3261   FREE                                                           

SOL3262

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3262   FREE                                                           

SOL3263

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3263   FREE                                                           

SOL3264

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3264   FREE                                                           

SOL3265

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3265   FREE                                                           

SOL3266

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3266   FREE                                                           

SOL3267

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3267   FREE                                                           

SOL3268

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3268   FREE                                                           

SOL3269

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3269   FREE                                                           

SOL3270

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3270   FREE                                                           

SOL3271

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3271   FREE                                                           

SOL3272

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3272   FREE                                                           

SOL3273

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3273   FREE                                                           

SOL3274

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3274   FREE                                                           

SOL3275

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3275   NO TEXT-INFORMATION FOR SU !                                   

SOL3276

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3276   FREE                                                           

SOL3277

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3277   FREE                                                           

SOL3500

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3500   CORRECTION OF MORE THAN 150 SG IMPOSSIBLE, TERMINATION OF ACTION

SOL3501

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3501   UTM-ERROR (&00) AT KDCS-CALL (&01)                             

SOL3502

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3502   TEXTFILE WITHOUT TEXT-CONTROL-LINE                             

SOL3503

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3503   TEXTLEVEL WRONG AT LINE (&00)                                  

SOL3504

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3504   WRONG FCBTYPE                                                  

SOL3505

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3505   (&00) RECORDS ARE TRUNCATED                                    

SOL3506

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3506   TEXT (&00) ALREADY IN DB (LINE (&01)) !                        

SOL3507

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3507   ERROR (&00) AT MACRO CALL UP FILE                              

SOL3508

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3508   ERROR (&00) AT WRITING OF BS2000 FILE                          

SOL3509

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3509   ERROR (&00) AT CLOSING OF BS2000 FILE                          

SOL3510

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3510   PLEASE ENTER FILE NAME                                         

SOL3511

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3511   NO USER ID ALLOWED IN FILE NAME !                              

SOL3512

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3512   *PARAMS/*PAREND: STRUCTURE ERROR AT LINE (&00)                 

SOL3513

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3513   %-CONTROL LINE FORMALLY WRONG AT LINE (&00)                    

SOL3514

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3514   *PARAMS/*PAREND ONLY WITH TEXT-7 ! LINE (&00)                  

SOL3515

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3515   PLEASE ENTER TEXT FIRST !                                      

SOL3516

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3516   ERROR (&00) IN FILE (&01) OCCURED !                            

SOL3517

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3517   ERROR AT FIELD STACK : RC = (&00) !                            

SOL3518

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3518   FILE ALREADY EXISTS ! ERROR: (&00)                             

SOL3519

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3519   TEXTLEVEL (&00) MULTIPLE DEFINED: (&01)                        

SOL3520

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3520   PLEASE ENTER VALID SEQUENCE                                    

SOL3521

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3521   PROCESSSING IDENTIFICATION MISSING OR WRONG !                  

SOL3522

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3522   PLEASE SELECT ONE PROCESSING ONLY                              

SOL3523

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3523   ENTERED LOGON PARAMETER WRONG                                  

SOL3524

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3524   NO FILES WITH THIS PREFIX AVAILABLE                            

SOL3525

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3525   VALUE MISSING OR NOT PERMISSIBLE (&00)                         

SOL3526

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3526   CAUTION ! FUNCTION "B" WILL DELETE THE WHOLE SU !              

SOL3527

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3527   SG NOT AVAILABLE (&00)                                         

SOL3528

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3528   SG (&00) ALREADY PRESENT                                       

SOL3529

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3529   NO AUTHORIZATION FOR USER (&00)                                

SOL3530

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3530   NO SC FOR TEXTFILE (&00) !                                     

SOL3531

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3531   W2LOGON NOT PREPARED FOR THIS SEQUENCE                         

SOL3532

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3532   ERROR (&00) AT START OF W2TNFS                                 

SOL3533

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3533   ERROR (&00) AT ENDING OF W2TNFS                                

SOL3534

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3534   AT NEW SU TAKE ON ONLY ONE SG IS PERMITTED                     

SOL3535

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3535   NOT AVAILABLE FOR CORRECTIONS                                  

SOL3536

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3536   SU/SG (&00) PRESENTLY SUSPENDED DUE TO CHANGE                  

SOL3537

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3537   PLEASE ENTER SU / SG RESPECTIVELY                              

SOL3538

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3538   PROCESSING OF MOVEMENT FILE HAS BEEN STARTED                   

SOL3539

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3539   SU WILL BE NEWLY SET UP                                        

SOL3540

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3540   ERROR (&00) AT MACRO CALL UP RELEASE                           

SOL3541

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3541   ERROR (&00) AT MACRO CALL UP ERASE                             

SOL3542

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3542   ERROR (&00) AT MACRO CALL UP CATALOG                           

SOL3543

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3543   ERROR (&00) AT MACRO CALL UP FILE                              

SOL3544

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3544   ERROR (&00) AT MACRO CALL UP FSTAT                             

SOL3545

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3545   ERROR (&00) AT MACRO CALL UP CMD                               

SOL3546

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3546   ERROR (&00) AT START OF (&01)                                  

SOL3547

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3547   ERROR (&00) AT READING OF DATA BASE HEADER RECORD              

SOL3548

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3548   ERROR AT WRITING OF DATA BASE RECORD                           

SOL3549

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3549   PASS OVER FOR NEW SC NOT POSSIBLE                              

SOL3550

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3550   ERROR (&00) AT WRITING OF SUPPLY GROUP RECORD                  

SOL3551

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3551   ERROR (&00) AT WRITING OF SUPPLY COMPONENT RECORD              

SOL3552

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3552   ERROR (&00) AT READING OF SUPPLY GROUP RECORD                  

SOL3553

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3553   ERROR (&00) AT WRITING OF SUPPLY GROUP RECORD                  

SOL3554

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3554   ERROR (&00) AT WRITING; FILE EMPTY                             

SOL3555

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3555   ERROR AT READING OF BS2000 FILE                                

SOL3556

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3556   ERROR (&00) AT WRITING OF LF RECORD                            

SOL3557

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3557   ERROR (&00) AT WRITING OF TEXT RECORD                          

SOL3558

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3558   ERROR (&00) AT WRITING OF CORRECTION RECORD                    

SOL3559

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3559   ERROR (&00) AT WRITING OF SUPPLY COMPONENT RECORD              

SOL3560

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3560   ERROR AT OPENING OF PARAMETER FILE                             

SOL3561

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3561   IDENTIFICATION ERROR AT PROCESSING PARAMETER FILE              

SOL3562

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3562   KEY ERROR (&00) AT PROCESSING OF PARAMETER FILE                

SOL3563

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3563   ERROR AT WRITE OF RECORD PACKET-REFERENCE                      

SOL3564

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3564   ERROR AT OPEN OF MOVEMENT FILE (&00)                           

SOL3565

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3565   ERROR AT PROCESSING OF MOVEMENT FILE (&00)                     

SOL3566

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3566   ERROR AT RELEASE OF MOVEMENT FILE                              

SOL3567

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3567   ERROR AT PROCESSING OF ENTER FILE                              

SOL3568

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3568   DELETION OF SC TO SUPPLIED SG NOT PERMITTED !                  

SOL3569

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3569   ERROR (&00) AT DELETION OF DB RECORD                           

SOL3570

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3570   ERROR AT (&00) CLOSE OF MOVEMENT FILE                          

SOL3571

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3571   ERROR (&00) AT WRITING OF MEDIUM RECORD                        

SOL3572

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3572   ERROR AT (&00) OPEN OF LIBRARY                                 

SOL3573

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3573   ERROR (&00) AT OPEN; LIBRARY LOCKED                            

SOL3574

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3574   ERROR (&00) AT SORTING !                                       

SOL3575

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3575   ERROR (&00) AT PASSWORD COMMAND !                              

SOL3576

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3576   SG (&00) NOT IN MOVEMENT FILE; TAKE ON 1 MISSING !             

SOL3577

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3577   ERROR (&00) AT THFS-FILE FOR ENTER                             

SOL3578

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3578   ERROR AT MEMORY SORT (&00)                                     

SOL3579

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3579   ERROR (&00) AT PROCESSING OF BS2000 FILE !                     

SOL3580

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3580   ERROR (&00) AT PROCESSING OF PARAMETER FILE !                  

SOL3581

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3581   ERROR (&00) AT OPENING OF ENTER FILE                           

SOL3582

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3582   ERROR (&00) AT CLOSING OF ENTER FILE                           

SOL3583

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3583   ERROR (&00) AT ACCESS FROM DB !                                

SOL3584

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3584   ERROR (&00) AT WRITING MOVEMENT FILE !                         

SOL3585

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3585   ERROR (&00) AT WRITING PROTOCOL FILE !                         

SOL3586

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3586   ERROR (&00) AT OPEN OF SPACE FILE!                             

SOL3587

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3587   ERROR (&00) AT WRITING OF SPACE FILE !                         

SOL3588

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3588   ERROR AT TAPE LENGTH CALCULATION !                             

SOL3589

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3589   ERROR AT CALL UP OF LIEF-ASYNCHRON !                           

SOL3590

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3590   ERROR (&00) AT W2TNFS CALL UP !                                

SOL3591

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3591   ERROR (&00) AT WRITING OF SUPPLY TEXT !                        

SOL3592

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3592   ERROR (&00) AT CMD-CALL: FILE !                                

SOL3593

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3593   ERROR (&00) AT CMD-CALL: ENTER !                               

SOL3594

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3594   ERROR (&00) AT CMD-CALL: RELEASE !                             

SOL3595

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3595   ERROR (&00) AT CMD-CALL: PASSWORD !                            

SOL3596

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3596   ERROR (&00) AT CMD-CALL: FSTAT !                               

SOL3597

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3597   ERROR (&00) AT CMD-CALL: SYNTAX !                              

SOL3598

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3598   ERROR (&00) AT CMD-CALL !                                      

SOL3599

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3599   ERROR (&00) AT CMD-CALL: ERASE !                               

SOL3600

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3600   ERROR (&00) AT CMD-CALL: CAT !                                 

SOL3601

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3601   ERROR (&00) AT MACRO CALL UP COPY                              

SOL3602

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3602   ERROR (&00) AT MACRO CALL UP ENAEI                             

SOL3603

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3603   PREFIX ALREADY PRESENT IN HOME PUBSET, PLEASE CHANGE !         

SOL3604

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3604   ERROR (&00) AT MACRO CALL UP ENAMP                             

SOL3605

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3605   ERROR (&00) AT MACRO CALL UP REQMP                             

SOL3606

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3606   FREE                                                           

SOL3607

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3607   FREE                                                           

SOL3608

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3608   ERROR (&00) AT MACRO CALL UP DISEI                             

SOL3609

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3609   ERROR (&00) AT MACRO CALL UP REMQ                              

SOL3610

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3610   ERROR (&00) AT MACRO CALL UP MGET                              

SOL3611

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3611   ERROR (&00) AT MACRO CALL UP DISMP: ENAMP MISSING              

SOL3612

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3612   ERROR (&00) AT MACRO CALL UP DISMP: OPERAND ERROR              

SOL3613

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3613   ERROR (&00) AT MACRO CALL UP DISMP: NOT ALLOWED                

SOL3614

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3614   ERROR (&00) AT MACRO CALL UP POSSIG1 !                         

SOL3615

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3615   ERROR (&00) AT MACRO CALL UP SOLSIG1                           

SOL3616

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3616   ERROR (&00) AT MACRO CALL UP SOLSIG2                           

SOL3617

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3617   ERROR (&00) AT MACRO CALL UP POSSIG2 !                         

SOL3618

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3618   REQU. RESOURCES NOT AVAILABLE, REPEAT !                        

SOL3619

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3619   SU WILL BE CORRECTED                                           

SOL3620

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3620   (&00) IS NOT PROCESSED IN THIS SEQUENCE                        

SOL3621

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3621   (&00) NOT IN PRODUCT ADMINISTRATION                            

SOL3622

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3622   RESETTING AT CORRECTION ACQUISITION NOT POSSIBLE               

SOL3623

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3623   SU NOT AVAILABLE (&00)                                         

SOL3624

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3624   LB MUST BE ONLINE                                              

SOL3625

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3625   NO CORRECTION TO THIS SELECTION                                

SOL3626

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3626   CORRECTION NOT AVAILABLE                                       

SOL3627

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3627   PARAMETER STHB OF FMSG IS NOT NUMERIC !                        

SOL3628

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3628   WRONG FUNCTION                                                 

SOL3629

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3629   SG NOT CHAINED TO A SU !                                       

SOL3630

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3630   NO FURTHER INFORMATION                                         

SOL3631

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3631   SC-NAME (&00) > 30 DIGITS !                                    

SOL3632

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3632   SC-NAME (&00) INVALID !                                        

SOL3633

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3633   ONLY T9P, T9G , T-C1, T-C2, T-C3, T-C4, T-C5, T-C6 ALLOWED !   

SOL3634

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3634   NO FILES AVAILABLE WITH THIS PREFIX                            

SOL3635

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3635   SG ENTERED SEVERAL TIMES                                       

SOL3636

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3636   DIVIDING FORBIDDEN: SG-(&00) NOT EQUAL !                       

SOL3637

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3637   DBH DOES NOT KNOW DB (&00) !                                   

SOL3638

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3638   MAX. NUMBER SG PER SU EXCEEDED                                 

SOL3639

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3639   REALLY TERMINATE ?                                             

SOL3640

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3640   MAX. NUMBER OF ELEMENTS EXCEEDED                               

SOL3641

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3641   PLEASE SELECT ONE PROCESSING ONLY                              

SOL3642

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3642   PLEASE SELECT ONE PROCESSING                                   

SOL3643

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3643   WRONG INPUT FOR FIELD FILE RETRIEVAL                           

SOL3644

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3644   WRONG INPUT FOR FIELD ACCESS                                   

SOL3645

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3645   WRONG INPUT FOR FIELD SHARE                                    

SOL3646

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3646   IDENTIFICATION WRONG FORMALLY                                  

SOL3647

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3647   DELIVERY FOR (&00) ONLY PERMITTED FROM CENTRAL DEPOT !         

SOL3648

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3648   NO PREFIX PERMITTED                                            

SOL3649

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3649   WRONG INPUT FOR FIELD DEVICE                                   

SOL3650

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3650   ENTRY OF AN ARCHIVE NUMBER NOT PERMITTED                       

SOL3651

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3651   PLEASE ENTER A VSN                                             

SOL3652

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3652   PLEASE ENTER AN ARCHIVE NUMBER                                 

SOL3653

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3653   RETENTION PERIOD TOO BIG (MAX. TILL 31.12.1999) !              

SOL3654

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3654   PLEASE SELECT ONE PROCESSING ONLY                              

SOL3655

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3655   WRONG INPUT FOR FIELD PREFIX                                   

SOL3656

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3656   PLEASE SELECT ONE PROCESSING ONLY                              

SOL3657

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3657   INPUT PACKETNAME NOT ALLOWED                                   

SOL3658

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3658   DEPOSITORY NOT CATALOGUED !                                    

SOL3659

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3659   FILE NOT FOUND                                                 

SOL3660

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3660   ENTRY SG NOT PERMITTED, IF SU IS PRESET                        

SOL3661

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3661   PLEASE ENTER SC NAME                                           

SOL3662

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3662   WRONG INPUT FOR FIELD SUPPLY COMPONENT                         

SOL3663

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3663   PLEASE ENTER SG NAME                                           

SOL3664

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3664   WRONG INPUT FOR FIELD SC TYPE                                  

SOL3665

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3665   WRONG INPUT FOR FIELD SUSPENSION                               

SOL3666

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3666   WRONG INPUT FOR FIELD PACKET                                   

SOL3667

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3667   PLEASE ENTER FILE NAME DEPOSITORY                              

SOL3668

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3668   WRONG INPUT FOR FIELD DEPOSITORY                               

SOL3669

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3669   PLEASE FILL TABLE WITHOUT GAPS                                 

SOL3670

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3670   WRONG INPUT FOR FIELD LIB ELEMENTS                             

SOL3671

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3671   WRONG INPUT FOR FIELD TEXT                                     

SOL3672

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3672   FILENAME ONLY WITH FUNCTION S/L ALLOWED                        

SOL3673

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3673   WRONG INPUT FOR FIELD FILE NAME                                

SOL3674

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3674   DEPOSITORY N MAY ONLY BE ENTERED FOR NST-FILE !                

SOL3675

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3675   WRONG INPUT FOR INSTALLATION-NAME                              

SOL3676

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3676   WRONG INPUT FOR INSTALLATION-USERID                            

SOL3677

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3677   WRONG INPUT FOR FIELD SYSRES ID                                

SOL3678

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3678   WRONG INPUT FOR FIELD BACKUP LEVEL                             

SOL3679

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3679   INDICATE MCD ONLY IF A SG IS ENTERED !                         

SOL3680

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3680   SG ALREADY SUPPLIED, MCD L IS NOT VALID !                      

SOL3681

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3681   WRONG INPUT FOR FIELD SELECTION                                

SOL3682

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3682   INDICATE MCD ONLY IF A SC IS ENTERED !                         

SOL3683

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3683   WRONG INPUT IN FIELD SUPPLY GROUP                              

SOL3684

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3684   OTHER USID NOT ALLOWED IN DEPOSITORY !                         

SOL3685

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3685   READ PASSWORD NOT ALLOWED                                      

SOL3686

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3686   TABEL TO SMALL: SG IN MORE THAN (&00) SU !                     

SOL3687

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3687   WRITE PASSWORD NOT ALLOWED                                     

SOL3688

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3688   VALUE DOES NOT MATCH RU-FLEV                                   

SOL3689

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3689   PLEASE ENTER VALID SEQUENCE                                    

SOL3690

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3690   PLEASE ENTER VALID FUNCTION                                    

SOL3691

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3691   PLEASE ENTER SU OR SG                                          

SOL3692

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3692   PLEASE ENTER A SG VERSION                                      

SOL3693

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3693   PLEASE ENTER A SU VERSION                                      

SOL3694

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3694   ENTRY OF PREFIX ALLOWED ONLY FOR SU INDICATION                 

SOL3695

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3695   ENTRY OF SG VERSION NOT ALLOWED                                

SOL3696

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3696   INPUT CORRECTION ID NOT PERMITTED                              

SOL3697

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3697   INPUT SU VERSION NOT PERMITTED                                 

SOL3698

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3698   WRONG INPUT IN FIELD CORRECTION ID                             

SOL3699

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3699   PLEASE ENTER A USER IDENTIFICATION                             

SOL3700

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3700   PLEASE ENTER AN ACCOUNT NUMBER                                 

SOL3701

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3701   MN-DEVICE FROM FSTAT IS NOT IN THE DEV-TABLE !                 

SOL3702

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3702   NO FILE, CREATION DATE IS ZERO !                               

SOL3703

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3703   WRONG FCBTYPE IN FILE !                                        

SOL3704

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3704   CAT-ID IN DEPOSITORY TOO LONG (6 DIGITS) !                     

SOL3705

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3705   PLEASE SELECT ONE FUNCTION ONLY                                

SOL3706

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3706   INPUT OF VERSION ALLOWED FOR SC ONLY                           

SOL3707

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3707   INPUT TYPE ALLOWED FOR SC ONLY                                 

SOL3708

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3708   WRONG ACCESS FUNCTION ! MOVEMENT FILE                          

SOL3709

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3709   PLEASE SELECT ONE PROCESSING ONLY                              

SOL3710

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3710   LIST MUST BE ENTERED !                                         

SOL3711

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3711   WRONG INPUT IN FIELD SUPPLY UNIT                               

SOL3712

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3712   WRONG INPUT FOR FIELD RETENTION PERIOD                         

SOL3713

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3713   SEQCHK ! MOVEMENT FILE                                         

SOL3714

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3714   TAKE-ON 1 MISSING !                                            

SOL3715

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3715   MDPATH UND UPPATH DOES NOT REFER                               

SOL3716

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3716   FILE NOT PRESENT !                                             

SOL3717

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3717   MORE THAN 200 BS2000-COMMANDS TO PROCESS !                     

SOL3718

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3718   INPUT FOR SEQUENCE DBER NOT PERMITTED                          

SOL3719

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3719   PLEASE ENTER A TARGET COMPUTER                                 

SOL3720

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3720   FILE IS NOT SHAREABLE                                          

SOL3721

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3721   INSTALLATION FILE NAME > 38 BYTE                               

SOL3722

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3722   CATID NOT PERMITTED                                            

SOL3723

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3723   MAX. NUMBER OF USERS EXCEEDED                                  

SOL3724

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3724   NO TEXTS/ELEMENTS PRESENT (&00)                                

SOL3725

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3725   NO HANDLING CLERK FOR SU/SG PRESENT                            

SOL3726

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3726   NO CORRECTION FOR THIS CR-NO PRESENT                           

SOL3727

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3727   SG NOT ALLOCATED TO THIS SU !                                  

SOL3728

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3728   DELETION OF CURRENT CORRECTION PROHIBITED !                    

SOL3729

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3729   DELETION OF CORR TO MAC/MOD PROHIBITED !                       

SOL3730

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3730   DELETION OF NEW CORRECTION PROHIBITED                          

SOL3731

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3731   ERROR AT MACRO CALL UP REMQ                                    

SOL3732

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3732   LIBRARY CONTAINS NO ELEMENTS (&00) !                           

SOL3733

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3733   ONLY A OR B ARE ALLOWED IN FUNCTION !                          

SOL3734

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3734   ELEMENT NOT IN LIST OF CONTENTS OF THE LIBRARY !               

SOL3735

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3735   INPUT TEXT NOT PERMITTED                                       

SOL3736

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3736   INPUT CORRECTION NOT PERMITTED                                 

SOL3737

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3737   INDICATION OF HANDLING CLERK DOES NOT MAKE SENSE HERE !        

SOL3738

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3738   INPUT TEXT-ID ALLOWED FOR SC ONLY                              

SOL3739

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3739   INPUT SUSPENSION-ID ALLOWED FOR SC ONLY                        

SOL3740

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3740   INPUT SHARE ALLOWED FOR SC ONLY                                

SOL3741

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3741   INPUT ACCESS ALLOWED FOR SC ONLY                               

SOL3742

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3742   INPUT CORRECTION-ID ALLOWED FOR SC ONLY                        

SOL3743

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3743   PLEASE ENTER A HANDLING CLERK                                  

SOL3744

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3744   PLEASE SELECT A PROCESSING                                     

SOL3745

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3745   INPUT OF SU ALLOWED ONLY, IF SC EMPTY                          

SOL3746

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3746   WRONG INPUT FOR FIELD ELEMENT                                  

SOL3747

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3747   ALTERNATIVE USERID ONLY ALLOWED IN TEXTLEVEL 1 !               

SOL3748

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3748   WRONG INPUT IN FIELD LIST                                      

SOL3749

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3749   WRONG INPUT IN FIELD UPDATE STATE SK                           

SOL3750

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3750   WRONG INPUT FOR FIELD ELEMENT-ID                               

SOL3751

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3751   MAX. NUMBER OF SC EXCEEDED                                     

SOL3752

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3752   HANDLING CLERK NOT PRESENT                                     

SOL3753

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3753   NO "." IN PREFIX ALLOWED !                                     

SOL3754

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3754   FORCED DIALOGUE                                                

SOL3755

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3755   SC NOT EXISTING: PLEASE PASS OVER !                            

SOL3756

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3756   FUNKTION KEY NOT GENERATED                                     

SOL3757

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3757   LMR LIBRARY NOT CORRECT (" OMLIB ") !                          

SOL3758

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3758   NO LMR LIBRARY !                                               

SOL3759

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3759   NO MLU /LMS LIBRARY !                                          

SOL3760

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3760   UNEXPECTED EOF FOR MLU /LMS LIBRARY !                          

SOL3761

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3761   IDENTIFICATION ERROR AT PROCESSING OF LIBRARY                  

SOL3762

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3762   SC TYPE NO LIBRARY !                                           

SOL3763

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3763   THIS TRANSACTION IS TO BE STARTED VIA (&00) ONLY !             

SOL3764

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3764   WRONG INPUT IN FIELD FTAC                                      

SOL3765

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3765   SG ALREADY PRESENT !                                           

SOL3766

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3766   SC ENTERED MORE THAN ONCE !                                    

SOL3767

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3767   SC ALREADY PRESENT !                                           

SOL3768

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3768   SC (&00) NOT SET UP COMPLETELY                                 

SOL3769

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3769   SU/SG NOT PRESENT                                              

SOL3770

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3770   DELETION OF SG AT AUTOMATIC ACQUISITION NOT PERMITTED !        

SOL3771

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3771   SC NOT PRESENT                                                 

SOL3772

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3772   CHANGE OF DATE NOT ALLOWED !                                   

SOL3773

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3773   PLEASE INDICATE SG !                                           

SOL3774

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3774   PLEASE INDICATE SC !                                           

SOL3775

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3775   PLEASE INDICATE VERSION !                                      

SOL3776

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3776   NO HANDLING CLERK ALLOCATED !                                  

SOL3777

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3777   THESE ELEMENTS ARE MISSING !                                   

SOL3778

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3778   PARTLY QUALIFIED INPUT NOT PERMITTED                           

SOL3779

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3779   NO AUTHORIZATION TO DELIVER FROM (&00)                         

SOL3780

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3780   MAX. NUMBER OF SU EXCEEDED                                     

SOL3781

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3781   MAX. NUMBER OF SG EXCEEDED                                     

SOL3782

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3782   INPUT LIST NOT PERMITTED                                       

SOL3783

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3783   MID L NOT PERMITTED !                                          

SOL3784

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3784   INPUT SG NOT PERMITTED                                         

SOL3785

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3785   INPUT SC NOT PERMITTED                                         

SOL3786

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3786   MORE THAN 150 SG, PLEASE RESTRICT SELECTION !                  

SOL3787

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3787   INST-UID FOR SG (&00) IS AMBIGUOUS !                           

SOL3788

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3788   NO CORRECTIONS PRESENT (&00)                                   

SOL3789

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3789   NO SRC /OSM LIBRARY !                                          

SOL3790

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3790   UNEXPECTED EOF FOR SRC /OSM LIBRARY !                          

SOL3791

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3791   AT LEAST 1 ELEMENT MUST BE INDICATED !                         

SOL3792

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3792   WRONG INPUT IN FIELD NKEY                                      

SOL3793

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3793   MORE THEN 32767 TEXT-/ELEMENT RECORDS CAPTURED                 

SOL3794

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3794   CURRENT CORRECTION STATE (&00) IS ALREADY SET UP               

SOL3795

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3795   INPUT USERID NOT PERMITTED                                     

SOL3796

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3796   PREFIX IS TOO LONG                                             

SOL3797

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3797   DUPLICATE TO LAST VSN, SPECIFY ANOTHER !                       

SOL3798

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3798   NO SC FOUND FOR SG (&00)!                                      

SOL3799

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3799   INDICATION AT UNLOCKING INEFFECTIVE !                          

SOL3800

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3800   LOCKED SG CAN ONLY BE UNLOCKED !                               

SOL3801

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3801   DUPLICATE NOT ALLOWED FOR EXISTING SU                          

SOL3802

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3802   SG IS NOT SUSPENDED (LOCKED) !                                 

SOL3803

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3803   INPUT SG AT SELECTION SC IN SG NOT PERMITTED                   

SOL3804

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3804   WRONG INPUT IN FIELD UNLOCK                                    

SOL3805

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3805   DUPLICATE ELEMENT; ELEMENT NOT ADDED                           

SOL3806

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3806   WRONG INPUT FOR FIELD FUNCTION                                 

SOL3807

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3807   ACCESS AND SHARE MUST BE ENTERED TOGETHER !                    

SOL3808

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3808   ACCESSS ERROR ON FMSG FILE !                                   

SOL3809

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3809   UNLOCKING FORBIDDEN, PLEASE ENTER NEW CORR !                   

SOL3810

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3810   LMS: LIST OF CONTENTS EMPTY !                                  

SOL3811

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3811   LMS: ERROR (&00) AT TOCPRIM !                                  

SOL3812

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3812   LMS: ERROR (&00) AT TOC !                                      

SOL3813

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3813   LMS: ERROR (&00) AT INIT !                                     

SOL3814

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3814   LMS: ERROR (&00) AT END !                                      

SOL3815

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3815   LMS: ELEMENT NAME > 38 DIGITS !                                

SOL3816

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3816   LMS: WRONG ELEMENT TYPE !                                      

SOL3817

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3817   LMS: TOO MUTCH ELEMENTS                                        

SOL3818

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3818   LMS: DOUBLE ELEMENTS (&00)                                     

SOL3819

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3819   RECORD WAS DELETED IN THE MEANTIME                             

SOL3820

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3820   HANDLING CLERK ALREADY PRESENT                                 

SOL3821

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3821   OUTPUT MAXIMUM 120 RECORDS                                     

SOL3822

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3822   NO REPLY                                                       

SOL3823

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3823   NO CHANGE, RESPONS-NEW HAS NO ENTRY                            

SOL3824

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3824   NO CHANGE, RESPONS-OLD HAT NO SG AND SU                        

SOL3825

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3825   NO CHANGE, SU OR SG (&00) LOCKED                               

SOL3826

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3826   CONTROL PARAMETER NOT PRESENT                                  

SOL3827

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3827   EXPRESS DELIVERY IS NOT ALLOWED ! STKH = SPACE                 

SOL3828

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3828   INPUT MISSING                                                  

SOL3829

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3829   WRONG INPUT                                                    

SOL3830

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3830   MOD ROUTINE NOT PRESENT                                        

SOL3831

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3831   INVALID KEY AT FMSG PROCESSING                                 

SOL3832

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3832   FILE NAME WRONG                                                

SOL3833

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3833   NO AUTHORIZATION RECORD PRESENT                                

SOL3834

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3834   AUTHORIZATION RECORD CURRENTLY LOCKED; SES-STAT:               

SOL3835

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3835   SOLIS1-DBNAME IS NOT IN FMSG (&00)                             

SOL3836

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3836   UTM USER ALREADY PRESENT                                       

SOL3837

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3837   DELETION NOT PERMITTED !                                       

SOL3838

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3838   ONLY ST AND S0-S9 ALLOWED AS RANGE FOR PARAMETER !             

SOL3839

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3839   UPDATE FOR SG NOT ALLOWED                                      

SOL3840

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3840   NO INSTALLATION FOUND FOR THIS TYPE OF SUPPLY !                

SOL3841

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3841   SELECTION NOT CARRIED OUT !                                    

SOL3842

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3842   SUPPLY ROUTE NOT POSSIBLE !                                    

SOL3843

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3843   NO FURTHER SU SELECTION PERMITTED !                            

SOL3844

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3844   NO SU FOUND FOR THIS TYPE OF SUPPLY !                          

SOL3845

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3845   SELECTED SU NOT PRESENT IN SOLIS2 !                            

SOL3846

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3846   SU SELECTION > 100 !                                           

SOL3847

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3847   NO INSTALLATION IN SOLIS1 OR INSTALLATION ID MISSING !         

SOL3848

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3848   NO SELECTION MADE RESP. WRONGLY MADE !                         

SOL3849

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3849   SU CURRENTLY LOCKED BECAUSE OF UPDATE; TERMINATION !           

SOL3850

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3850   SG CURRENTLY LOCKED BECAUSE OF UPDATE; TERMINATION !           

SOL3851

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3851   SC CURRENTLY LOCKED BECAUSE OF UPDATE; TERMINATION !           

SOL3852

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3852   INDICATION CU-DOC ONLY PERMITTED FOR SUPPLY INFO !             

SOL3853

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3853   SUPPLY INFO ONLY ALLOWED FOR ONE INSTALLATION !                

SOL3854

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3854   PARTLY QUALIFIED SU ALLOWED AT PERSONAL SELECTION ONLY !       

SOL3855

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3855   NO VALID DEVICE TYPE PRESENT  !                                

SOL3856

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3856   WRONG ARCHIVE BLKSIZE IN SOLIS1 INSTALLATION RECORD !          

SOL3857

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3857   MTC SUPPLY IS PERMITTED FOR ONE INSTALLATION ONLY !            

SOL3858

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3858   PLEASE USE DEVICE TYPE (&00) !                                 

SOL3859

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3859   DEVICE TYPE CHANGE NOT ALLOWED ANY MORE !                      

SOL3860

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3860   SC > TAPE LENGTH; ENTER LONGER TAPE-TYPE !                     

SOL3861

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3861   WRONG TRANSACTION INPUT !                                      

SOL3862

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3862   SPACELIMIT OF DELIVERY EXCEEDED ! PACKET: (&00)                

SOL3863

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3863   WRONG INPUT FOR FIELD DATE                                     

SOL3864

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3864   NO PACKET RECORD FOUND !                                       

SOL3865

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3865   NO RECORD DUE FOR DELETION FOUND !                             

SOL3866

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3866   PLEASE ENTER LIST TYPE !                                       

SOL3867

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3867   WRONG INPUT FOR FIELD PACKET                                   

SOL3868

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3868   PACKET RECORD NOT PRESENT !                                    

SOL3869

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3869   NO LIST TO BE PRINTED FOUND !                                  

SOL3870

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3870   ENTER "PACKET PROCESSING" GENERATED                            

SOL3871

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3871   NO AUTHORIZATION FOR THIS FUNCTION                             

SOL3872

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3872   MOVEMENT FILE PROCESSED !                                      

SOL3873

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3873   PLEASE ENTER PACKET !                                          

SOL3874

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3874   MOVEMENT FILE NOT PRESENT !                                    

SOL3875

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3875   ZUGR ERROR1!                                                   

SOL3876

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3876   PLEASE MARK A SU                                               

SOL3877

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3877   WRONG INPUT FOR FIELD COMPLETE                                 

SOL3878

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3878   PLEASE ENTER POSSIBLE SEQUENCE !                               

SOL3879

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3879   SU (&00) NOT IN MOVEMENT FILE; TAKE ON 1 MISSING !             

SOL3880

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3880   FTAC INPUT NOT POSSIBLE IN THE FORM X 'AA' !                 

SOL3881

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3881   PLEASE ENTER PREFIX/FILE !                                     

SOL3882

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3882   PLEASE ENTER EARGET COMPUTER !                                 

SOL3883

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3883   PLEASE ENTER FTAC OR USER IDENTIFICATION !                     

SOL3884

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3884   PLEASE ENTER USER IDENTIFICATION !                             

SOL3885

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3885   PLEASE ENTER ACCOUNT NUMBER !                                  

SOL3886

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3886   FILE NOT PRESENT OR CAT ERROR !                                

SOL3887

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3887   FUNCTION NOT PERMITTED HERE !                                  

SOL3888

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3888   ELEMENT TRUNCATED AFTER 38 DIGITS                              

SOL3889

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3889   NEW ELEMENTS MISSING IN DELTA-LIB !                            

SOL3890

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3890   SU/SG NEW MUST BE UNEQUAL TO SU/SG OLD !                       

SOL3891

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3891   BLKCTRL: (&00) DOES NOT MATCH LBRINONKEY (&01)                 

SOL3892

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3892   FILES WITH (&00) EXISTING IN (&01) !                           

SOL3893

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3893   DBH DOES NOT KNOW TABLE (&00) !                                

SOL3894

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3894   NO AUTHORIZATION TO DELIVER FROM REGION (&00)                  

SOL3895

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3895   REGIONENDATEN: ERROR (&00)                                     

SOL3896

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3896   ADDITIONAL SU NOT ALLOWED FOR CORRECTION                       

SOL3897

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3897   ATTENTION ! THIS DELIVERY IS NOT COMPLETE !                    

SOL3898

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3898   PLEASE ENTER SG NAME AND VERSION                               

SOL3899

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3899   PLEASE ENTER SU NAME AND VERSION                               

SOL3900

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3900   SYSSII: INVALID FILENAME                                       

SOL3901

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3901   SYSSII: INVALID PARAMETER LIST VERSION                         

SOL3902

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3902   SYSSII: OUTPUT AREA LENGTH TOO SHORT                           

SOL3903

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3903   SYSSII: INVALID FUNCTION CALLED                                

SOL3904

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3904   SYSSII: INVALID FORMAT                                         

SOL3905

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3905   SYSSII: DMS ERROR (&00)                                        

SOL3906

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3906   SYSSII: FILE NOT OPEN                                          

SOL3907

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3907   SYSSII: SYSTEM ERROR                                           

SOL3908

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3908   SYSSII: INTERNAL ERROR                                         

SOL3909

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3909   SYSSII: VERSION < V02.0A                                       

SOL3910

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3910   PLEASE ENTER SU NAME                                           

SOL3911

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3911   PLEASE ENTER SU NAME AND SU VERSION ONLY                       

SOL3912

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3912   PLEASE ENTER SG NAME AND SG VERSION ONLY                       

SOL3913

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3913   WRONG INPUT IN FIELD DELETE                                    

SOL3914

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3914   THIS SU CONTAINS NO SG!                                        

SOL3915

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3915   TABEL TO SMALL: MORE THAN (&00) SG IN SU !                     

SOL3916

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3916   ERROR AT CREATION OF THE W2MPREST MEMORY POOL!                 

SOL3917

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3917   PROBLEM WITH THE W2MPREST MEMORY POOL!                         

SOL3918

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3918   SU NEW MUST BE UNEQUAL TO SU OLD!                              

SOL3919

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3919   THE STRUCTURE OF THE TWO SU MUST BE THE SAME!                  

SOL3920

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3920   VERSAND ADDRESS (&00) NOT FOUND!                               

SOL3921

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3921   WRONG INPUT FOR FIELD TEXT!                                    

SOL3922

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3922   PLEASE SELECT A KIND OF ROUTE!                                 

SOL3923

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3923   PLEASE SELECT ONLY ONE OF THE 3 FIELDS!                        

SOL3924

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3924   DELIVERY DATE CAN NOT BE SPECIFIED IN THIS SITUATION!          

SOL3925

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3925   DELIVERY TIME CAN NOT BE SPECIFIED IN THIS SITUATION!          

SOL3926

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3926   DELIVERY DATE MUST BE SPECIFIED!                               

SOL3927

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3927   ATTENTION: DIVERGENT DISPATCH ADDRESS!

SOL3928

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3928   BUT TO THE FOLLOWING DISPATCH ADDRESS:

SOL3929

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3929   WRONG INPUT FOR FIELD CORRECTION STATE                         

SOL3930

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3930   ACCESSS ERROR (&00) ON FILE (&01)!                             

SOL3931

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3931   PLEASE FILL THE EMPTY LINE(S) BEFORE TO CONTINUE!              

SOL3932

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3932   WRONG INPUT FOR FIELD RU-NAME                                  

SOL3933

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3933   WRONG INPUT FOR FIELD VERSION                                  

SOL3934

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3934   WRONG INPUT FOR FIELD CORRSTATE                                

SOL3935

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3935   WRONG INPUT FOR FIELD KZ                                       

SOL3936

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3936   WRONG INPUT FOR FIELD SYS                                      

SOL3937

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3937   WRONG INPUT FOR FIELD TID                                      

SOL3938

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3938   ILLEGAL COMBINATION OF FIELDS SYS AND TID                      

SOL3939

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3939   ERROR DURING CHECK OF THE CONFIGURATION. SEE (&00) REPORT!     

SOL3940

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3940   ERROR: THIS LE CAN NOT RUN ON ANY VERSION!!!                   

SOL3941

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3941   ERROR (&00) AT OPENING OF REPORT FILE (&01)                    

SOL3942

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3942   THE CHECK OF THE CONFIGURATION IS OK

SOL3943

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3943   THE VALUE CANNOT BE CHANGED TO "J"

SOL3944

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL3944   THE CHECK OF THE CONFIGURATION IS OK WITH WARNING. SEE (&00).

SOL9999

Destination: USER-TASK             Routing code:                     Weight: 99

Warranty   : NO

SOL9999   (&00) (&01) (&02) (&03) (&04) (&05) (&06) (&07) (&08) (&09)