SVR
SVR0000
Destination: CONSOLE (
Warranty : NO
SVR0000 (&00) started with device (&01), console (&02), BS2-Sys (&03)
Meaning
&00 = IPL, DIPL or VIPL
The IPL has been started. BS2000 is loaded from device &01, &02 is defined as the
console, and &03 is used as the BS2000 system name.
SVR0001
Destination: CONSOLE (
Warranty : NO
SVR0001 (&00) returncode: IPL OK
Meaning
&00 = IPL, DIPL or VIPL
IPL was performed without errors. BS2000 has been started.
SVR0002
Destination: CONSOLE (
Warranty : NO
SVR0002 (&00) returncode: (&01)
Meaning
&00 = IPL, DIPL or VIPL IPL was aborted with an error (&01 = cause of error).
Response
Eliminate the error and recommence IPL.
SVR0003
Destination: CONSOLE (
Warranty : NO
SVR0003 unknown (&00) returncode: (&01)
Meaning
&00 = IPL, DIPL or VIPL, &01 = Return code IPL was aborted with an unspecified error code.
Response
Back up the RMAssist Trace and send it to the Support Center for diagnosis
(var/opt/SMAW/X2000/tmp/rma_trace*) or create new diagnostic data via the SEM.
SVR0004
Destination: CONSOLE (
Warranty : NO
SVR0004 START-(&00) aborted
Meaning
&00 = IPL, DIPL or VIPL The IPL has been aborted.
Response
Recommence IPL. If this does not help, reboot the system.
SVR0005
Destination: CONSOLE (
Warranty : NO
SVR0005 START-(&00) aborted ((&01))
Meaning
&00 = IPL, DIPL or VIPL
IPL was aborted with errors (&01 = cause of error).
Response
Recommence IPL. If this does not help, eliminate the errors. A reboot of the system may suffice.
SVR0006
Destination: CONSOLE (
Warranty : NO
SVR0006 invalid command (&00)
Meaning
&00 = incorrect RMAssist command
An incorrect command was entered.
Response
Notify Customer Support.
SVR0007
Destination: CONSOLE (
Warranty : NO
SVR0007 WARNING: Console device for IPL with VMID=(&00) cannot be checked
Meaning
The specified VMID is wrong or is not configured.
Response
Enter the right VMID.
SVR0008
Destination: CONSOLE (
Warranty : NO
SVR0008 (&00) started
Meaning
&00 = IOHDUMP or IVMDUMP
IOHDUMP or IVMDUMP has been started.
SVR0010
Destination: CONSOLE (
Warranty : NO
SVR0010 WARNING: IPL INFO FOR VMID (&00) cannot be written - IPL continues"
Meaning
The info file with the IPL data could not be written.
SVR0011
Destination: CONSOLE (
Warranty : NO
SVR0011 NO IPL - bs2000 guest system in hold state
Meaning
The BS2000 guest system is in the STOP status.
Response
Re-initialize and start the guest system.
SVR0012
Destination: CONSOLE (
Warranty : NO
SVR0012 IOHDUMP=(&00)
Meaning
IOHDUMP &00 is created.
SVR0013
Destination: CONSOLE (
Warranty : NO
SVR0013 IOHDUMP finished: OK
Meaning
IOHDUMP has been completed.
SVR0015
Destination: CONSOLE (
Warranty : NO
SVR0015 IOHDUMP finished with error
Meaning
Generation of the IOHDUMP was not completed.
Response
Repeat IOHDUMP
SVR0016
Destination: CONSOLE (
Warranty : NO
SVR0016 IVMDUMP=(&00)
Meaning
IVMDUMP &00 is being generated.
SVR0017
Destination: CONSOLE (
Warranty : NO
SVR0017 IVMDUMP ist fertiggestellt
Meaning
IVMDUMP &00 is being generated.
SVR0018
Destination: CONSOLE (
Warranty : NO
SVR0018 IVMDUMP finished with error
Meaning
IVMDUMP was not completed.
SVR0040
Destination: CONSOLE (
Warranty : NO
SVR0040 MDEBUG is running - no action
Meaning
The mdebug program is loaded. The specified command is not executed.
Response
Terminate the mdebug program.
SVR0042
Destination: CONSOLE (
Warranty : NO
SVR0042 (&00)-Parameter error - no start of IPL
Meaning
&00 = IPL, DIPL or VIPL
An incorrect parameter was entered in the IPL.
Response
Enter the parameter/data correctly.
SVR0048
Destination: CONSOLE (
Warranty : NO
SVR0048 error by SLED DUMP
Meaning
An error occurred when generating or writing a SLED DUMP.
Response
Repeat the DIPL.