RFA0001
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0001 SYSAFR. DATE '(&00)'
Meaning
(&00): creation date in the form YYYY/MM/DD.
RFA0002
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0002 COMMAND PROCESSING COMPLETED
Meaning
The command /SET-RFA-CONNECTION or
/REMOVE-RFA-CONNECTION or
/SHOW-RFA-CONNECTIONS has been executed successfully.
RFA0003
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0003 ERROR '(&00)'. COMMAND PROCESSING ABORTED
Meaning
Error (&00) occurred during the processing of the
/SET-RFA-CONNECTION or /REMOVE-RFA-CONNECTION command.
In a procedure all commands are rejected until /SET-JOB-STEP
or /LOGOFF.
(&00): error code.
01: possible reasons:
- incomplete MRSCAT entry.
- invalid MRSCAT entry.
- the remote MRSCAT status is INACCESSIBLE.
Contact the system administrator.
02: catalog identifier not found in MRSCAT.
The system administrator has to create the MRSCAT entry.
03: /SET-RFA-CONNECTION with the cat ID of the user default pubset is
not possible if the user default pubset is a shared pubset.
04: the /REMOVE-RFA-CONNECTION command is rejected because no
/SET-RFA-CONNECTION command has been issued before.
05: error during creation of RFA bourses and contingencies.
06: RFA connection inoperable.
Terminate the connection with the /REMOVE-RFA-CONNECTION command and
create a new one with the /SET-RFA-CONNECTION command.
07: BCAM did not answer within a specified time limit.
08: the /SET-RFA-CONNECTION command cannot be executed because the user
already has established the maximum number of 16 RFA connections.
09: insufficient class 5 memory for RFA tables.
Repeat the /SET-RFA-CONNECTION command later.
0A: shortage of BCAM.
Possible reasons:
- limit of BCAM applications,
- limit of BCAM connections,
- BCAM requests to try the action later.
Possible reason:
- the remote processor does not run.
- The local host is not known to BCAM in the partner system.
Cases 1 and 2: contact the system administrator.
0B: BCAM shutdown warning.
0C: BCAM shutdown finished.
0D: BCAM not active.
Contact the system administrator.
0E: unknown partner or unknown application $DIALOG on partner.
The host name found in the MRSCAT entry is not known to BCAM,
or the application $DIALOG on partner is not known to BCAM.
Contact the system administrator.
0F: request of connection has been rejected.
Contact the system administrator.
10: the operator disconnects BCAM.
Contact the system administrator.
11: error during creation of the partner task.
Possible reasons:
- error in the protocol.
- File $SYSAFR missing, not share or not cataloged on the
default user ID.
- The versions of $SYSAFR and the remote BS2000 do not fit together.
- User ID or account number unknown to the remote system.
- Invalid password.
Contact the system administrator
to install the (correct) file $SYSAFR or
to make file $SYSAFR share or
to establish the missing user ID and account number in the remote
system or
correct the command.
12: the /REMOVE-RFA-CONNECTION command is rejected while a program
is loaded.
Terminate the program and try the command again.
13: BCAM buffer too small.
BCAM has been generated with a buffer size which is not big enough
for RFA.
Contact the system administrator.
14: error during a read from a terminal:
a hardware error or the terminal is disconnected.
Try the command again.
15: for shared pubsets the user IDs of /SET-RFA-CONNECTION,
/SET-LOGON-PARAMETERS and the AFR partner task have to be the same.
Contact the system administrator to give a
/MODIFY-MASTER-CATALOG-ENTRY with SHARED-PUBSET=NO
for this catalog identifier.
RFA0004
Destination: USER-TASK, CONSOLE Routing code: R Weight: 70
Warranty : NO
RFA0004 RFA BCAM CONNECTION ERROR '(&00)'
Meaning
BCAM has detected an error.
This message is sent to the console for diagnostic purposes.
(&00): BCAM information word.
RFA0005
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0005 WARNING: COMMAND REJECTED FOR IMPORTED CATALOG
Meaning
The user issued a /SET-RFA-CONNECTION command for an imported catalog.
Files on public volumes are not accessible.
RFA0006
Destination: USER-TASK Routing code: Weight: 30
Warranty : NO
RFA0006 RFA PROTOCOL ERROR. RFA PARTNER TASK TERMINATED WITH DUMP
Meaning
The partner task SYSAFR detected an error in the RFA protocol.
RFA0007
Destination: USER-TASK Routing code: Weight: 30
Warranty : NO
RFA0007 CATALOG NOT AVAILABLE. INVALID HOST NAME
Meaning
The MRS catalog entry with the catalog identifier specified
in the /SET-RFA-CONNECTION command contains an invalid host name.
Response
Contact the system administrator to correct the host name.
RFA0008
Destination: USER-TASK Routing code: Weight: 30
Warranty : NO
RFA0008 SPECIFY CATALOG IDENTIFIER
Meaning
The mandatory operand <catalog identifier> in the
/SET-RFA-CONNECTION or /REMOVE-RFA-CONNECTION has not been specified.
Response
Repeat the command with a catalog identifier.
RFA0009
Destination: USER-TASK Routing code: Weight: 30
Warranty : NO
RFA0009 UNKNOWN OPERAND
Meaning
The /SET-RFA-CONNECTION or /REMOVE-RFA-CONNECTION command contains
an unknown operand.
Response
Compare the command with the description in the manual and correct it.
RFA0010
Destination: USER-TASK Routing code: Weight: 30
Warranty : NO
RFA0010 INVALID KEYWORD
Meaning
The /SET-RFA-CONNECTION or /REMOVE-RFA-CONNECTION command contains
an invalid keyword.
Response
Compare the command with the description in the manual and correct it.
RFA0011
Destination: USER-TASK Routing code: Weight: 30
Warranty : NO
RFA0011 INVALID OPERAND '(&00)'
Meaning
The displayed operand in the /SET-RFA-CONNECTION or
/REMOVE-RFA-CONNECTION command has an invalid value.
(&00): Name of operand
CATALOG-ID
USER-IDENTIFICATION
ACCOUNT
PASSWORD
CONNECTION
ANSWER.
Response
Compare the operand with the description in the manual and correct it.
RFA0012
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0012 ERROR IN RFA OR IN TASK TABLES OR MEMORY MANAGEMENT
Meaning
Possible reasons:
- A software error was detected during RFA processing.
- A request or release memory was terminated with system error.
- When trying to get a task specific or job specific information
an error was detected.
Response
Contact system diagnosis if the reason of this error is unexplainable.
RFA0013
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0013 NO REMOTE PARTNER. SYSAFR ABORTED
Meaning
RDATA has been rejected with operand error.
This indicates that SYSAFR has been executed by a local user, which
cannot be done successfully. SYSAFR must be executed by a partner system.
RFA0014
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0014 COMMAND NOT KNOWN IN REMOTE SYSTEM
Meaning
A command, which was transmitted by RFA, is not known in the
remote system on account of the SDF system syntax file or on account
of the SDF user syntax file belonging to the user ID specified in the
/SET-RFA-CONNECTION command.
RFA0015
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0015 PLEASE ENTER REPLY TO MESSAGE FROM '(&00)'
Meaning
RFA asks the user to enter his answer to the message from
the remote system, which has just been displayed.
(&00): catalog identifier of the remote system.
Response
Enter reply.
RFA0016
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0016 VERSION OF REMOTE SYSTEM IS NOT SUPPORTED
Meaning
A connection to the remote BS2000 version by RFA is not supported.
RFA0017
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0017 NO ACTIVE RFA CONNECTIONS
Meaning
There are no active RFA connections for this user identification.
RFA0018
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0018 NO RFA CONNECTION
Meaning
There does not exist any RFA connection to the given catalog identifier.
RFA0019
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0019 WARNING: OUTPUT CUT
Meaning
The output to SYSOUT is not complete.
RFA0020
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0020 OUTPUT ERROR
Meaning
An error occurred when giving the output to SYSOUT.
RFA0021
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0021 NO BCAM NAME
Meaning
The own (local) BCAM name could not be found out.
RFA0022
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0022 SYSAFR (&00) NEEDS BS2000 (&01). BS2000 (&02) ACTIVE. SYSAFR ABORTED
Response
Contact the system administrator to install the right SYSAFR.
RFA0023
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0023 RFA CONNECTION INOPERABLE.
Meaning
The RFA connection is not established correctly; it is inoperable.
Response
Terminate the connection with /REMOVE-RFA-CONNECTION and create a new
one with /SET-RFA-CONNECTION.
RFA0024
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0024 NO ADDITIONAL RFA CONNECTION POSSIBLE.
Meaning
The maximum number of RFA connections is already established.
RFA0025
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0025 PROGRAM LOADED. COMMAND PROCESSING ABORTED.
Meaning
The command /REMOVE-RFA-CONNECTION is rejected while a program is
loaded.
Response
Terminate the program and try the command again.
RFA0026
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0026 COMMAND REJECTED FOR A SHARED PUBSET.
Meaning
The SET-RFA-CONNNECTION command is rejected when the catalog identifier
specifies a shared pubset and
- the catalog identifier specifies the user default pubset or
- the userids of /SET-RFA-CONNECTION, /SET-LOGON-PARAMETERS and the
AFR partnertask are not the same.
RFA0027
Destination: USER-TASK Routing code: Weight: 99
Warranty : NO
RFA0027 RFA CONFIGURATION ERROR.
Meaning
During the command processing an error occurred in the RFA configuration.
For example
- the host name is missing in the MRSCAT entry or
- the partner host is unknown to BCAM.
Response
For more detail look at the obtained message RFA0003 and
contact the system or network administrator if necessary.