NGCCOPY

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGCCOPY   COPYRIGHT (C) (&00) (&01). ALL RIGHTS RESERVED

NGCLOAD

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGCLOAD   Program '(&00)', Version '(&01)' of '(&02)' loaded from file '(&03)'

NGCSTRT

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGCSTRT   Procedure '(&00)', Version '(&01)' of '(&02)' started from file '(&03)'

NGC0A00

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A00   (&01) VERSION (&00) READY

Meaning

End of program initialization phase.

NGC0A01

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 98

Warranty   : NO

NGC0A01   ENTER '(&00)' STATEMENT

Meaning

IOGEN expects a control statement.

Response

Enter an IOGEN statement.

NGC0A02

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A02   (&01) TERMINATED (&00)

Meaning

The program has terminated (normally or abnormally).
(&00): NORMALLY: without errors
       (PLEASE CHECK MESSAGES!): with errors

Response

See error messages in the case of an abnormal termination.

NGC0A03

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A03   '(&00)' GENERATED

Meaning

The IOCGEN run has been completed; the PAM file is generated.

NGC0A04

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A04   NUMBER OF GENERATED (&00)-UNITS : (&01)

NGC0A11

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A11   IOGEN INTERNAL ERROR IN '(&00)'. ERROR CODE: (&01)

Meaning

Internal function (&00) issued an error Code (&01).

Response

Send an error notice to the diagnosis department.

NGC0A20

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A20   '(&00)' TABLE OVERFLOW

Meaning

Too many statements of the specified type.

Response

Reduce the number of statements of the specified type.

NGC0A21

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A21   MORE THAN (&00) SYSFILE STATEMENTS READ. ALL SUBSEQUENT SYSFILE STATEMENTS IGNORED

Meaning

Too many SYSFILE statements have been issued.

NGC0A22

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A22   (&00) STATEMENT ON WRONG PLACE. STATEMENT IS IGNORED

Meaning

The statement cannot be accepted on this place. It is ignored.

NGC0A29

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A29   OBSOLETE VALUE '(&03)' OF '(&02)' OPERAND IN '(&01)' STMT REPLACED BY '(&00)'

Meaning

(&00): new value
(&01): statement
(&02): operand
(&03): specified (obsolete) value.

NGC0A3A

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A3A   NO REPLACEMENT OF FILE '(&00)' REQUESTED

Meaning

IOGEN detected that the file (&00) exists. In the CPGOPT statement
REPLACE=N
has been specified, so the file (&00) may not be replaced.

Response

Erase or rename the file (&00), or specify REPLACE=Y in the CPGOPT
statement.

NGC0A30

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A30   VALUE '(&02)' OF '(&01)' OPERAND IN '(&00)' STATEMENT INVALID. (&03)

Meaning

(&00): statement
(&01): operand
(&02): specified value
(&03): further information

Response

Correct input.

NGC0A31

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A31   MISSING '(&01)' OPERAND IN '(&00)' STATEMENT

Meaning

(&00): statement
(&01): operand.

NGC0A32

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A32   STATEMENT '(&00)' IS INVALID (&01)

Meaning

The statement (&00) specified by the user was not a valid
IOGEN statement.

Response

Enter a correct statement.

NGC0A33

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A33   STATEMENT '(&00)' IS PRIVILEGED

NGC0A34

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A34   SYNTAX ERROR IN PRECEDING STATEMENT

NGC0A35

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A35   DUPLICATE '(&00)' STATEMENT. ONLY THE FIRST ONE WILL BE PROCESSED

NGC0A36

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A36   MANDATORY '(&00)' STATEMENT IS MISSING

Response

Wait for further messages.

NGC0A37

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A37   DUPLICATE VALUE '(&02)' OF '(&01)' OPERAND IN '(&00)' STATEMENT

Meaning

The operand (&01) has already been specified in the same or another
statement (&00).

Response

Wait for further message.

NGC0A38

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A38   TOO MANY '(&01)' OPERANDS IN '(&00)' STATEMENT

Meaning

The maximum permissible number of the specified operands is restricted
and has been exceeded.
(&00): name of the erroneous IOGEN statement.
(&01): name of an operand in this statement.

Response

Correct operand(s).

NGC0A39

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A39   '(&02)' OPERAND INVALID IN '(&01)' STATEMENT DUE TO '(&00)'

Response

Correct the operand, if necessary.

NGC0A40

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A40   PRECEDING STATEMENT IS IGNORED

NGC0A41

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A41   DEFAULT VALUE '(&00)' ASSUMED

NGC0A42

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A42   END OF INPUT IS ASSUMED BY IOGEN

NGC0A43

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A43   SUBSEQUENT STATEMENTS OF TYPE '(&00)' ARE IGNORED

NGC0A44

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A44   *** IOGEN PROCESS ABORTED WITH UNDEFINED RESULT ***

Response

Correct errors and restart IOGEN.

NGC0A45

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A45   '(&00)' OPERAND IS IGNORED (&01)

Response

Correct the operand, if necessary.

NGC0A46

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A46   LOGICAL CONTROL UNIT SPEC. ERROR FOUND WHILE PROCESSING C.U.

Meaning

IOCGEN found a specification error while building a logical control unit.
A logical control unit can have a maximum of 4 channel paths, max. 4
physical control units and max. 32 devices. Max. 256 logical control units
are allowed.

Response

Correct unit attachments and rerun IOGEN.

NGC0A47

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A47   MORE THAN 16 LOGICAL CONTROL UNITS ASSIGNED TO CHANNEL '(&00)'

Meaning

IOCGEN has found more than 16 logical control units assigned to channel
mnemonic (&00). A maximum of 16 logical control units can be assigned to
one channel.

Response

Ensure that no more than 16 logical control units are assigned to one
channel and rerun IOGEN.

NGC0A48

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A48   ADDRESS OF DEVICE '(&00)' EXCEEDS ADDRESS RANGE OF THE CONTROL UNIT '(&01)'

Meaning

The address of the device (&00) is outside of the valid
address range of the control unit (&01).
IOGEN stops processing.

Response

Correct unit attachments and rerun IOGEN.

NGC0A49

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A49   INCORRECT PAV-DEFINITION FOR DEVICE '(&00)'.  REASON: '(&01)'

Meaning

The device (&00) was defined as PAV-device without 
a valid BASE-device.

Response

Check hardware configuration.

NGC0A50

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A50   ATTACHMENT MNEMONIC '(&00)' OF '(&01)' UNIT '(&02)' NOT DEFINED IN '(&03)' TABLE

Meaning

(&00): attachment mnemonic
(&01): type of unit to be attached (DEVICE or CONTROLLER)
(&02): mnemonic of unit to be attached.
(&03): type of attachment unit expected (CTL or CHN).

Response

Correct input and rerun IOGEN.

NGC0A51

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A51   NO '(&00)' IS ATTACHED TO '(&01)' UNIT '(&02)'

Meaning

A unit ( CHN or CTL) is defined without any unit attached to it.
(&00): type of units to be attached (CONTROLLER or DEVICE)
(&01): type of incorrectly defined unit (CHN or CTL)
(&02): mnemonic of incorrectly defined unit.

Response

Wait for further messages.

NGC0A52

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A52   '(&00)' UNIT '(&01)' IS IGNORED

Meaning

The specified hardware unit is not generated into the system.
(&00): unit type (DVC, CTL or CHN)
(&01): unit mnemonic.

Response

Correct the error, if necessary, and rerun IOGEN.

NGC0A53

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A53   '(&00)' UNIT '(&01)' IS ATTACHED TO '(&02)' OF DIFFERENT TYPES

Meaning

A hardware unit is attached to channels or controllers of
different types.
(&00): unit type (DEVICE or CONTROLLER)
(&01): unit mnemonic
(&02): type of attachment units (CONTROLLERS or CHANNELS).

Response

Correct the error and rerun IOGEN.

NGC0A54

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A54   DEVICES '(&00)' AND '(&01)' HAVE THE SAME DEVICE ADDRESS

Meaning

(&00),(&01): device mnemonics.

Response

Correct input and rerun IOGEN.

NGC0A56

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A56   INCONSISTENT (&00) CONFIGURATION

Meaning

The hardware or console configuration is inconsistent. Specific messages
have already been displayed.
(&00): HARDWARE or CONSOLE.

Response

Correct input and rerun IOGEN.

NGC0A57

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A57   '(&00)' UNIT '(&01)' IS ATTACHED TO '(&02)' UNIT '(&03)' OF WRONG TYPE

Response

Correct input and rerun IOGEN.

NGC0A58

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A58   '(&00)' UNIT '(&01)' AND '(&02)' UNIT '(&03)' ARE ATTACHED TO DIFFERENT '(&04)' UNITS

Meaning

The (&00) unit (&01) and the (&02) unit (&03) have to be attached to
the same (&04) unit.
(&01)(&03) : mnemonics of device units
(&04)      : CONTROLLER or CHANNEL or CTL/CHN.

Response

Correct input and rerun IOGEN.

NGC0A59

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A59   ADDRESS RANGE OVERLAP OF THE CONTROL UNITS '(&00)' AND '(&01)'

Meaning

Conflicting address ranges were found for these control units.
Configuration may cause a hardware error.
IOGEN stops  processing.

Response

Check hardware configuration.

NGC0A60

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A60   CONTROL UNITS '(&00)' AND '(&01)' HAVE THE SAME WWPN AT CHANNEL '(&02)'

Meaning

(&00),(&01): controller mnemonics.
Conflicting WWPN (target-id) definitions were found for 
these control units at the given channel.

Response

Change hardware definitions and rerun IOGEN.

NGC0A61

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A61   DEVICE ATTACHMENTS OF CONTROL UNIT '(&00)' HAVE DIFFERENT VALUES IN THE HIGHER BYTE OF THE LUN

Meaning

(&00): controller mnemonic.
At the given control unit there exist device attachments,
for which the higher bytes of the 2-byte-LUN (logical unit
number) are not identical. This is not allowed.

Response

Change hardware definitions and rerun IOGEN.

NGC0A62

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A62   CONTROL UNITS '(&00)' AND '(&01)' HAVE THE SAME WWPN AND IDENTICAL VALUES IN THE HIGHER BYTE OF THE LUN OF THE ATTACHED DEVICES

Meaning

(&00),(&01): controller mnemonics.
In case of identical WWPN definitions for two or more control
units the higher byte of the LUN of the attached devices 
must be different for every control unit.

Response

Change hardware definitions and rerun IOGEN.

NGC0A63

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A63   DIRECT CONNECTED CONTROL UNIT '(&00)' NOT SINGLE AT  CHANNEL '(&01)'

Meaning

(&00): controller mnemonic.
(&01): channel path identifier of the channel.
The specified control unit was defined as direct connected
to a type FC channel. Additional connections to this
channel are not possible.

Response

Change hardware definitions and rerun IOGEN.

NGC0A64

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A64   DEVICES WITH DIFFERENT TIMEOUT REQUIREMENTS AT CONTROL UNIT '(&00)'

Meaning

(&00): controller mnemonic.
Devices with different timeout requirements are
attached to this controller.
The parameter for the timeout handling in the
channel system is only possible on the controller
level. IOGEN sets the parameter to inhibit timeout
actions for this controller.

Response

If possible, use separate controllers for devices
with different requirements.

NGC0A65

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A65   TAPES COMBINED WITH DISKS AT CHANNEL '(&00)'

Meaning

(&00): channel path identifier of the channel.
Combining tapes with disks at
a type FC channel may lead to timeout
problems in the FC protocol of the channel.

Response

Use a separate FC channel for tape connections.

NGC0A66

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A66   IDENTICAL LUN(S) AT CONTROLLERS '(&00)' AND '(&01)'  TO CHANNEL '(&02)'

Meaning

The named controllers are connected with the same port
(WWPN) to the same channel(s) and they have at least one
common LUN. This configuration is not possible.
IOGEN stops  processing.
(&00),(&01): Mnemonics and WWPN of the controllers
(&02): CHANNEL-PATH-ID of one of the channels

Response

Correct input and rerun IOGEN.

NGC0A67

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A67   NOT ALLOWED COMBINATION OF DEVICES AT CONTROLLER '(&00)'

Meaning

The mix of FAST-DPAV alias devices and other devices at the same
logical controller is not supported.

Response

Correct hardware configuration.

NGC0A68

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A68   NO BASE DEVICES FOR ALIAS DEVICE(S) '(&00)' AT CONTROLLER '(&01)'

Meaning

The named alias devices shall be used for FAST-DPAV, but
there are no matching base devices. The base devices
must have identical channel connections as the alias devices
and their device numbers must be lower than those of
the alias devices.

Response

Correct hardware configuration.

NGC0A69

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0A69   NOT ALLOWED COMBINATION OF CONTROLLER ATTACHMENTS AT CHANNEL '(&00)'

Meaning

The mix of direct attached controller and controller that
are attached via switch to a type FC channel is not possible.

Response

Correct hardware configuration.

NGC0I30

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0I30   INPUT RECORD EXCEEDS 1024 BYTES. RECORD TRUNCATED

Response

Correct input.

NGC0I33

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0I33   INPUT NESTING DEPTH IS '(&00)'. NO HIGHER VALUES PERMITTED

Meaning

The nesting depth of the input files has been exceeded.

NGC0I34

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0I34   FILE '(&00)' IS NOT CATALOGED OR EMPTY

Meaning

An empty or non-existing file was specified in a SYSFILE statement.
(&00): name of the incorrect file.

Response

Correct input.

NGC0I35

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0I35   FILE '(&00)' IS IN USE

Meaning

(&00): name of the locked file.

Response

Rerun IOGEN later.

NGC0I36

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0I36   FILE '(&00)' IS NOT OF TYPE ISAM/SAM

Meaning

A file of wrong type was specified in a SYSFILE  statement.
(&00): name of the incorrect file.

Response

Correct input.

NGC0001

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0001   ALLOCATION OF MORE MEMORY FAILED

Meaning

Alloction of more memory by calling alloc/realloc failed

NGC0010

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0010   INTERNAL ERROR IN CALLING MSG7X

Meaning

MSG7X-hiding routine of IOGEN or IOCGEN reports an error
Possible are
erroneous parameterlist of hiding routine
erroneous parameterlist of MSG7X-call

NGC0011

Destination: USER-TASK             Routing code:                     Weight:  

Warranty   : NO

NGC0011   ERROR ON SYSLST

Meaning

Error during writing on SYSLST.

NGC0024

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0024   IOCF GENERATOR VERSION (&00) READY

NGC0025

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0025   (&00) GENERATED

NGC0026

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0026   (&00) NORMALLY TERMINATED

Meaning

The program has normally terminated.

NGC0027

Destination: USER-TASK             Routing code:                     Weight:  

Warranty   : NO

NGC0027   IOCGEN terminated abnormally

NGC0050

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0050   DMS ERROR ON FILE '(&00)' DURING '(&01)'. DMS ERROR CODE = (&02). ERROR INF IN SYSTEM MODE: /HELP-MESS OR /HELP (&02)

Meaning

For more detailed information on the DMS error enter the /HELP-MESS or
/HELP command in system mode or see the manual 'System Messages',
'DMS Disk Processing', or 'DMS Tape Processing'.

NGC0051

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0051   SYSTEM-SYNTAXFILE MODIFIED (NOT ACTIVATED)

Meaning

SINPRC.IOGEN was called for modification (not activation) of IOGEN system
syntax file

NGC0052

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0052   IOGEN SYSSPR FILE MODIFIED

Meaning

SINPRC.IOGEN was called for modification of IOGEN SYSSPR file

NGC0053

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC0053   IOGEN USER-SYNTAXFILE MODIFIED

Meaning

SINPRC.IOGEN was called for modification of IOGEN user syntax
file

NGC1001

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1001   ALLOCATION OF MORE MEMORY FAILED

Meaning

Alloction of more memory by calling alloc/realloc failed

NGC1002

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1002   STATEMENT CAN NOT BE IDENTIFIED

NGC1003

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1003   INTERNAL IOCGEN ERROR: WRONG SIZE-SPECIFICATION IN FREE_UPD OR IN FR_INT_U

NGC1004

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1004   END STATEMENT IS MISSING

NGC1005

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1005   WRONG CHANNEL TYPE IS SPECIFIED

NGC1006

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1006   CHPID IS MULTIPLE DEFINED

NGC1007

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1007   CHANNEL CONNECTION NOT FOUND

NGC1008

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1008   RDATA REPORTS ERROR

NGC1009

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1009   CMPG SIZE OVERFLOW

NGC1010

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1010   CONTROLLER MNEMONIC IS MULTIPLE DEFINED

NGC1011

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1011   CONTROLLER CONNECTION NOT FOUND

NGC1012

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1012   ERROR IN OPENING OF IOCF FILE

NGC1013

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1013   ERROR IN WRITING THE IOCF FILE

NGC1014

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1014   FIRST STATEMENT MUST BE FOR-STATEMENT

NGC1015

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1015   CREATION OF IOCF FILE FAILED

NGC1016

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1016   INTERNAL ERROR IN CALCULATION OF DEVICE PATHS

NGC1017

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1017   CLOSING OF IOCF FILE FAILED

NGC1018

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1018   OPENING OF SYSLST FAILED

NGC1019

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1019   FOR-STATEMENT CONTAINS WRONG IOCF IDENTIFIER

NGC1020

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1020   INT_EBC INPUT ERROR

NGC1021

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1021   CTL LIST IS CREATED WITH ERRORS

NGC1022

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1022   SYSTEM CALL REPORTS ERROR BY SET-FILE-LINK OF IOCF PAM-FILE

NGC1025

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC1025   (&00) GENERATED

NGC1026

Destination: USER-TASK             Routing code:                     Weight:  

Warranty   : NO

NGC1026   Overrun allowable IORSF length

Meaning

The configuration is too large. Thereby the allowable length of IORSF
is overrun.

NGC2010

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC2010   INCORRECT ORDER OF STATEMENTS

Meaning

The order of the statements for the program is incorrect.

NGC2011

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC2011   LOGICAL CONTROL UNIT SPEC. ERROR FOUND WHILE PROCESSING C.U.

Meaning

IOCGEN found a specification error while building a logical control unit.
Look up the maximal values in the manual.

Response

Correct unit attachments and rerun IOGEN.

NGC2012

Destination: USER-TASK, CONSOLE    Routing code: A                   Weight: 50

Warranty   : NO

NGC2012   MORE THAN 16 LOGICAL CONTROL UNITS ASSIGNED TO CHANNEL '(&00)'

Meaning

IOCGEN has found more than 16 logical control units assigned to channel
mnemonic (&00). A maximum of 16 logical control units can be assigned to
one channel.

Response

Ensure that no more than 16 logical control units are assigned to one
channel and rerun IOGEN.